Lowrance electronic installation instructions EP-80R TH Configuration, Boat Setup Reset

Page 10

3.If you selected a configuration with more than one tank you will have to select the tank you want to set up and press MENU, which will open the Tank Size window. (If you choose a single-tank configuration, you will not have to choose the tank. You will be directed straight to the Tank Size window covered in Step 4.)

4.Use the UP and DOWN keys to input the number of gallons the tank will hold and press MENU. Repeat steps 3 and 4 for each additional tank. After all tanks have been set up, you will be directed to the main display.

Boat Setup Reset

If you want to access the Setup screen (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configu- ration to default settings.

To reset engine tank configuration:

1.Press MENU, highlight SYSTEM SETUP and press MENU.

2.Choose ENG/TANK and press MENU twice. The following message will appear: Hit menu to reset Eng/Tnk.

3.Press MENU. The Setup screen will appear with Boat Setup high- lighted.

EP-80R TH Configuration

The EP-80R TH temperature sensor has three configuration options: Inside, Outside and Water. An unconfigured temperature sensor will appear on the Bus Devices list as UnCfg Temp.

To configure a temp sensor:

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press MENU.

2.Highlight B. DEVICES and press MENU. After a few moments the Bus Devices list will appear.

3.Highlight UNCFG TEMP and press MENU. The following message will appear: Hit Menu to Cfg Temp Sns.

4.Press MENU to be taken to the Selecting Temp menu, which will have three options: Inside, Outside and Water.

5.Highlight the desired temp option and press MENU. The temp sensor has now has been configured. You will be directed to the Bus Devices list.

NOTE:

If your temp sensor is not updated on the Bus Devices list, refresh the list by letting it time out and then access it again.

10

Image 10
Contents EP-80R TH Tools and Supplies Installation Recommended Tools and suppliesPage Connecting to a Nmea 2000 Network Network Backbone and Network Nodes Adding a Network Node Additional Network InformationPage LMF-200 EP-80R TH Temp Configuration Boat SetupEP-80R TH Configuration Boat Setup ResetTo reconfigure a temp sensor Displaying EP-80R TH Temp Sensor Data Screen RotationCustomizing Pages Page LMF-400 EP-80R TH Temp Configuration To reset engine-tank configuration Message will appear Press Menu to UnConfig Device Name Displaying EP-80R TH Temp Sensor data To add a page to the display To customize Quad Analog To customize Quad Digital Page Bus Setup Nmea 2000 Menu/Networking MenuEP-80R TH Temp Sensor Configuration Device NameTo reset device name to default setting Unconfiguring a Temp Sensor Reconfiguring a temp sensorDisplaying EP-80R TH Temp Sensor Information Page Page Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle