Lowrance electronic EP-80R TH Message will appear Press Menu to UnConfig Device Name

Page 17

3.Choose the desired temp sensor and press ENTER. Select UNCONFIGURE from the temp configuration menu and press ENTER. The following

message will appear: Press Menu to UnConfig Device Name.

4.Press ENTER to unconfigure the sensor and be directed to the Bus Devices list where the temp now will be listed as UnCfg Temp.

Bus Devices highlighted in the System Setup menu (left). Searching

Bus Devices window (center) with Bus Devices list (right). To reconfigure a temp sensor:

To reconfigure a sensor, there must be a configuration name available (Water, Outside or Inside). If all three temp sensors have been config- ured, you will have to unconfigure a temp sensor to make its name available for reconfiguration. If you try to reconfigure a sensor when the desired configuration name is in use, a Name Already Selected mes- sage will appear.

If all three temps are configured — meaning there is no name configura- tion available — follow the first set of instructions. If the desired con- figuration name is available, follow the second set of instructions.

The first set of instructions below will show you how to switch the con- figuration of a water temp to an outside temp.

If all temps configured (Configuration name unavailable):

1.Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and press ENTER.

2.Highlight BUS DEVICES and press ENTER. Select OUTSIDE TEMP and press ENTER to open the temp configuration menu.

3.Select UNCONFIGURE and press ENTER. The following message will ap- pear: Press Enter to UnConfig Device Name.

4.Press ENTER to unconfigure the sensor and be directed to the Bus Devices list. The Outside temp is now unconfigured and will be dis- played as UnCfg Temp. Its configuration name (Outside) is now avail- able, so you will be able to use it to reconfigure the Water temp sensor.

5.Highlight WATER TEMP and press ENTER, which will open the temp

17

Image 17
Contents EP-80R TH Tools and Supplies Recommended Tools and supplies InstallationPage Connecting to a Nmea 2000 Network Network Backbone and Network Nodes Additional Network Information Adding a Network NodePage Boat Setup LMF-200 EP-80R TH Temp ConfigurationBoat Setup Reset EP-80R TH ConfigurationTo reconfigure a temp sensor Screen Rotation Displaying EP-80R TH Temp Sensor DataCustomizing Pages Page LMF-400 EP-80R TH Temp Configuration To reset engine-tank configuration Message will appear Press Menu to UnConfig Device Name Displaying EP-80R TH Temp Sensor data To add a page to the display To customize Quad Analog To customize Quad Digital Page Nmea 2000 Menu/Networking Menu Bus SetupDevice Name EP-80R TH Temp Sensor ConfigurationTo reset device name to default setting Reconfiguring a temp sensor Unconfiguring a Temp SensorDisplaying EP-80R TH Temp Sensor Information Page Page Page Lowrance Electronics Full ONE-YEAR Warranty For Lowrance 800-324-1356. For Eagle How to Obtain Service…