Lowrance electronic EP-80R TH Adding a Network Node, Additional Network Information

Page 7

All T connectors on your network probably will be connected to a device. If you want to add another node to a working network, add another T connector. T connectors may be purchased from LEI (ordering informa- tion appears on the back page of this booklet). If you are adding a Lowrance or LEI NMEA 2000 sensor, it will come with a T connector.

Adding a Network Node

You can add a node to any existing connection, anywhere along the net- work backbone. This connection could be between a T connector and a terminator, between two T connectors, between a T connector and a backbone extension cable or between two extension cables. Wherever you want to add the new node, separate the sockets of the existing connection and install the T connector between them.

If you want to add a node at the end of the backbone (network bus) re- move the terminator from the last connector, like the figure above. In- stall the new T connector and attach the terminator to the side of the connector.

Use T-connector or double T connector to add

Backbone cable

device to bus (maintaining linear architecture)

to rest of bus

Attach terminator at end of bus

Existing network node

Devices connect to double T connector

In this example, a new device is added to the NMEA 2000 bus by install- ing a T connector between a T connector and a terminator at the end of the backbone (network bus).

Additional Network Information

For more information on creating or expanding a network refer to the NMEA 2000 network setup booklet, part number 988-0154-173, which came packed with this document.

7

Image 7
Contents EP-80R TH Tools and Supplies Recommended Tools and supplies InstallationPage Connecting to a Nmea 2000 Network Network Backbone and Network Nodes Additional Network Information Adding a Network NodePage Boat Setup LMF-200 EP-80R TH Temp ConfigurationBoat Setup Reset EP-80R TH ConfigurationTo reconfigure a temp sensor Screen Rotation Displaying EP-80R TH Temp Sensor DataCustomizing Pages Page LMF-400 EP-80R TH Temp Configuration To reset engine-tank configuration Message will appear Press Menu to UnConfig Device Name Displaying EP-80R TH Temp Sensor data To add a page to the display To customize Quad Analog To customize Quad Digital Page Nmea 2000 Menu/Networking Menu Bus SetupDevice Name EP-80R TH Temp Sensor ConfigurationTo reset device name to default setting Reconfiguring a temp sensor Unconfiguring a Temp SensorDisplaying EP-80R TH Temp Sensor Information Page Page Page Lowrance Electronics Full ONE-YEAR Warranty For Lowrance 800-324-1356. For Eagle How to Obtain Service…