Lowrance electronic EP-80R TH installation instructions

Page 4

Afterwards, clean the area around the hole with detergent or alcohol. This will establish a good surface for the adhesive.

5.Using a high quality, marine-grade above- or below-waterline seal- ant/adhesive compound, apply a 1/8" (3 mm) bead of sealant around the lip of the EP-80R TH housing.

6.Make sure the nut has been removed from the sensor module, then from the outside of the transom, pass the EP-80R TH cable through the hole and push the housing with sealant into it. Use a twisting motion to squeeze out excess sealant. Remove excess sealant from the outside of the transom before it dries.

Slide the nut over the red connector (left); Place the nut on the sensor

module, add sealant on the inside of the hull and tighten the nut

(right).

7.On the inside of the hull, slide the nut over the back end of the sen- sor module and add a 1/8" bead of sealant around the edge of the hole on the inside of the transom. Hand-tighten the nut; be careful not to over-tighten. Do not use a wrench to tighten the nut! Remove ex- cess sealant from the inside of the hull before it dries.

8.Route the EP-80R TH cable to the T on the network backbone where you intend to attach it, and plug it in.

NOTE:

Allow marine grade sealant/adhesive compound to dry for 12 hours before taking your boat out on the water.

9.Check for leaks! After the boat is placed in the water, check for leaks immediately. Check the boat for leaks again several times during the next 24 hours. If you notice any leakage at all, the EP-80R TH should be re-installed with a new coat of adhesive.

4

Image 4
Contents EP-80R TH Tools and Supplies Installation Recommended Tools and suppliesPage Connecting to a Nmea 2000 Network Network Backbone and Network Nodes Adding a Network Node Additional Network InformationPage LMF-200 EP-80R TH Temp Configuration Boat SetupEP-80R TH Configuration Boat Setup ResetTo reconfigure a temp sensor Displaying EP-80R TH Temp Sensor Data Screen RotationCustomizing Pages Page LMF-400 EP-80R TH Temp Configuration To reset engine-tank configuration Message will appear Press Menu to UnConfig Device Name Displaying EP-80R TH Temp Sensor data To add a page to the display To customize Quad Analog To customize Quad Digital Page Bus Setup Nmea 2000 Menu/Networking MenuEP-80R TH Temp Sensor Configuration Device NameTo reset device name to default setting Unconfiguring a Temp Sensor Reconfiguring a temp sensorDisplaying EP-80R TH Temp Sensor Information Page Page Page Lowrance Electronics Full ONE-YEAR Warranty How to Obtain Service… For Lowrance 800-324-1356. For Eagle