GSW 72090 Valve is dripping or leaking, have a, Licensed plumber repair it, Do not plug valve

Page 12

COLD WATER INLET

PIPE INSULATION

HOT WATER

OUTLET

TEMPERED

WATER TO

FIXTURE

FOLLOW THE TEMPERING VALVE MANUFACTURER'S INSTRUCTIONS

TEMPERING

VALVE (SET TO

49°C (120°F))

1.Install a diaphragm-type expansion tank that is suitable for potable water on the cold water supply line. The expansion tank must have a minimum capacity of 5.7 litres (1.5 US gallons) for every 190 litres (50 US gal- lons) of stored water and be rated for 150 psi or the working pressure of the water heater.

2.Install a pressure relief valve rated at max 125 psi in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and protected from freezing. Contact the local water supplier or plumbing inspector for information on how to control this situation.

Important: Do not plug the temperature and pressure relief valve.

Temperature and Pressure (T&P) Relief Valve

WARNING

Explosion Hazard

• If the temperature and pressure relief

Figure 11 Typical Tempering Valve Installation

Important: Always use a good grade of joint compound, approved for use with potable water systems, and be certain that all fittings are drawn up tight.

Important: Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove, modify or tamper with the heat traps or any inserts within the heat traps.

Please note the following:

DO NOT install this water heater with iron piping. The sys- tem should be installed only with new piping that is suitable for potable (drinkable) water such as copper, CPVC or poly- butylene. DO NOT use PVC water piping.

DO NOT use any pumps, valves or fittings that are not com- patible with potable water.

DO NOT use valves that may cause excessive restriction to water flow. Use full flow ball or gate valves only.

DO NOT use any lead based solder in potable water lines. Use appropriate tin-antimony or other equivalent material. DO NOT use with piping that has been treated with chro- mates, boiler seal or other chemicals.

DO NOT add any chemicals to the system piping that will contaminate the potable water supply.

Closed System/Thermal Expansion

Periodic discharge from the temperature and pressure relief valve may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve. This will create a closed water system. During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase. This may cause the temperature and pressure relief valve to dis- charge small quantities of hot water. To prevent this from happening, there are two recommendations:

valve is dripping or leaking, have a

licensed plumber repair it.

• Do not plug valve.

• Do not remove valve.

• Failure to follow these instructions can

result in death or an explosion.

Refer to Figure 12 for a typical T&P valve installation. Important: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.

TEMPERATURE

AND PRESSURE

RELIEF VALVE

DISCHARGE LINE 19mm (3/4 in.)

MIN. DO NOT CAP OR PLUG.

Figure 12 Typical Temperature & Pressure Relief Valve Installation

– 12 –

Image 12
Contents For Your Safety What to do if YOU Smell GASPage Viii Troubleshooting Guide IX Repair Parts IllustrationLimited Warranty Introduction II Safety For Installations in CanadaFor Installations in the United States User ResponsibilitiesSafety Warning Flammable Vapours Safety Warning ScaldingSafety Warning Carbon Monoxide Backflow PreventionClearances and Accessibility Location RequirementsEarthquake Zones Failure to Properly Install this Heater MAY Gas SupplyResult in a Fire Hazard Gas Leak Testing Gas PressureGas line purging Confined Space Air Requirements for Canadian Installations Air RequirementsLocal Codes Confined Space Air Requirements for Installations Exhaust Venting Water SupplyValve is dripping or leaking, have a Licensed plumber repair itDo not plug valve Do not remove valveInstallations Check Temperature And Pressure Relief ValveDischarge Line IV Operating Instructions Water Temperature Regulation Temperature AdjustmentLighting Instructions Robertshaw 110R What to do if YOU Smell GASLighting Instructions Robertshaw 220R Lighting Instructions White-Rodgers 37C AvantOperation Burner Flames Emergency Shut DownChecking the Draft Operating ConditionsVI Maintenance Draining and FlushingPeriodic Inspection External Cleaning Flame-arrester Resetting and Replacing the Safety TCO SwitchTemperature and Pressure Relief Valve VII Combo Heating System RequirementsViii Troubleshooting Guide Problem Possible Causes CorrectionThermostat Fails to Shut IX Repair Parts Illustration Repair PartsLimited Warranty WHO is CoveredHOW the Original Owner can Make a Warranty Claim

72090 specifications

The GSW 72090 is a remarkable addition to the world of modern heating solutions, designed to provide efficient and effective space heating. It epitomizes advanced technology, reliability, and user-centric design, making it an ideal choice for homes and commercial spaces alike.

One of the main features of the GSW 72090 is its impressive heating capacity. Engineered to deliver optimal warmth, it can efficiently heat larger areas, ensuring that spaces remain comfortable even during the coldest months. The unit’s high-grade alloy construction enhances durability and helps maintain consistent performance over time.

A vital technology integrated into the GSW 72090 is its modulating control system. This system intelligently adjusts the temperature output based on the current heating demand, optimizing energy usage and contributing to lower utility bills. This efficiency not only benefits the consumer but also has a positive impact on the environment by reducing greenhouse gas emissions.

The GSW 72090 also boasts a sleek and modern aesthetic, making it an attractive addition to any space. Its design allows for easy installation and maintenance, ensuring that users can focus on comfort without worrying about the complexities of upkeep. The unit operates quietly, providing a peaceful environment without the disruptive noises often associated with traditional heating systems.

Incorporating safety features is another key characteristic of the GSW 72090. It includes overheat protection, which automatically turns the unit off if it detects excessive temperatures, ensuring a safe environment for occupants. Additionally, the product is constructed with materials that are resistant to corrosion and wear, enhancing longevity.

As an environmentally conscious option, the GSW 72090 is designed to comply with stringent energy efficiency regulations. Its performance not only meets but often exceeds the required standards, making it a smart choice for those looking to reduce their carbon footprint.

Overall, the GSW 72090 stands out due to its combination of advanced technologies, user-friendly features, aesthetic appeal, and commitment to safety and efficiency. Its multi-faceted capabilities make it a prime option for anyone seeking reliable and effective heating solutions in their home or business.