GSW Water Heater Parts Manual - IX Repair Overview

Page 24

IX) REPAIR PARTS ILLUSTRATION

1.

NIPPLE-HOT OUTLET

 

 

 

2.

NIPPLE-COLD INLET

 

 

 

3.

DRAFTHOOD

 

 

 

4.

TEMPERATURE & PRESSURE

 

 

 

 

RELIEF VALVE

1

2

 

5.

REDUCER RING

7

6.

ANODE

 

 

6

7.DIP TUBE

8.FLUE BAFFLE

9.

DRAIN VALVE

3

10.

BURNER/MANIFOLD ASSEMBLY

 

11.

GAS CONTROL/THERMOSTAT

 

12.

OUTER DOOR

5

13.

IGNITER

 

14.

TCO SWITCH

 

15.FLEXIBLE MANIFOLD TUBE

16.HEAT SHIELD (60 GALLON ONLY)

13

8

11

QUICK CONNECT LEADS

 

 

12

 

 

4

 

 

 

 

 

 

9

 

 

 

15

14

10

16

 

 

 

 

 

 

 

 

 

 

 

Figure 20 Repair Parts

 

 

 

 

 

 

 

 

 

 

 

 

14.

TCO SWITCH

 

 

 

 

 

17.

PILOT/THERMOCOUPLE ASSEMBLY

 

 

17

 

25

18.

VIEWPORT

 

 

 

 

 

19.

TWO PIECE GROMMET WITH CLIP

 

 

 

 

 

20.

MANIFOLD DOOR

 

 

 

 

 

21.

GAS MANIFOLD

 

 

 

 

 

22.

PILOT TUBE

 

 

22

 

23

23.

GAS ORIFICE

18

 

 

 

 

 

 

24.

MANIFOLD DOOR GASKET

 

 

 

21

 

 

 

 

25.

BURNER

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

14

20

24

Figure 21 Manifold/Door Assembly

 

 

 

 

 

 

 

 

 

 

 

 

– 24 –

Image 24
Contents For Your Safety What to do if YOU Smell GASPage Viii Troubleshooting Guide IX Repair Parts IllustrationLimited Warranty Introduction II Safety For Installations in CanadaFor Installations in the United States User ResponsibilitiesSafety Warning Flammable Vapours Safety Warning ScaldingSafety Warning Carbon Monoxide Backflow PreventionClearances and Accessibility Location RequirementsEarthquake Zones Failure to Properly Install this Heater MAY Gas SupplyResult in a Fire Hazard Gas Leak Testing Gas PressureGas line purging Confined Space Air Requirements for Canadian Installations Air RequirementsLocal Codes Confined Space Air Requirements for Installations Exhaust Venting Water SupplyValve is dripping or leaking, have a Licensed plumber repair itDo not plug valve Do not remove valveInstallations Check Temperature And Pressure Relief ValveDischarge Line IV Operating Instructions Water Temperature Regulation Temperature AdjustmentLighting Instructions Robertshaw 110R What to do if YOU Smell GASLighting Instructions Robertshaw 220R Lighting Instructions White-Rodgers 37C AvantOperation Burner Flames Emergency Shut DownChecking the Draft Operating ConditionsVI Maintenance Draining and FlushingPeriodic Inspection External Cleaning Flame-arrester Resetting and Replacing the Safety TCO SwitchTemperature and Pressure Relief Valve VII Combo Heating System RequirementsViii Troubleshooting Guide Problem Possible Causes CorrectionThermostat Fails to Shut IX Repair Parts Illustration Repair PartsLimited Warranty WHO is CoveredHOW the Original Owner can Make a Warranty Claim

72090 specifications

The GSW 72090 is a remarkable addition to the world of modern heating solutions, designed to provide efficient and effective space heating. It epitomizes advanced technology, reliability, and user-centric design, making it an ideal choice for homes and commercial spaces alike.

One of the main features of the GSW 72090 is its impressive heating capacity. Engineered to deliver optimal warmth, it can efficiently heat larger areas, ensuring that spaces remain comfortable even during the coldest months. The unit’s high-grade alloy construction enhances durability and helps maintain consistent performance over time.

A vital technology integrated into the GSW 72090 is its modulating control system. This system intelligently adjusts the temperature output based on the current heating demand, optimizing energy usage and contributing to lower utility bills. This efficiency not only benefits the consumer but also has a positive impact on the environment by reducing greenhouse gas emissions.

The GSW 72090 also boasts a sleek and modern aesthetic, making it an attractive addition to any space. Its design allows for easy installation and maintenance, ensuring that users can focus on comfort without worrying about the complexities of upkeep. The unit operates quietly, providing a peaceful environment without the disruptive noises often associated with traditional heating systems.

Incorporating safety features is another key characteristic of the GSW 72090. It includes overheat protection, which automatically turns the unit off if it detects excessive temperatures, ensuring a safe environment for occupants. Additionally, the product is constructed with materials that are resistant to corrosion and wear, enhancing longevity.

As an environmentally conscious option, the GSW 72090 is designed to comply with stringent energy efficiency regulations. Its performance not only meets but often exceeds the required standards, making it a smart choice for those looking to reduce their carbon footprint.

Overall, the GSW 72090 stands out due to its combination of advanced technologies, user-friendly features, aesthetic appeal, and commitment to safety and efficiency. Its multi-faceted capabilities make it a prime option for anyone seeking reliable and effective heating solutions in their home or business.