GSW 72090 manual Lighting Instructions Robertshaw 220R

Page 16

Lighting Instructions (Robertshaw 220R)

FOR YOUR SAFETY READ BEFORE OPERATING

 

WARNING: If you do not follow these instructions

o Immediately call your gas supplier from a neighbor’s

 

exactly, a fire or explosion may result causing proper-

phone. Follow the gas supplier’s instructions.

 

ty damage, personal injury or loss of life.

o If you cannot reach your gas supplier, call the fire depart-

 

 

ment.

A. This appliance has a pilot which must be lighted by an

 

igniter. When lighting a pilot, follow these instructions

C. Use only your hand to turn the gas control knob. Never

exactly.

use tools. If the knob will not turn by hand, don’t try to

B. BEFORE OPERATING smell all around the appliance

repair it, call a qualified service technician. Force or

attempted repair may result in a fire or explosion.

area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

D. Do not use this appliance if any part has been under

WHAT TO DO IF YOU SMELL GAS

water. Immediately call a qualified service technician to

inspect the appliance and to replace any part of the control

o

Do not try to light any appliance.

o

Do not touch any electric switch; do not use any

system and any gas control which has been under water.

phone in your building.

LIGHTING INSTRUCTIONS

1.STOP! Read all safety labels on the water heater before operation.

2.Remove the outer door.

3.Turn the temperature dial counterclockwise to its low- est setting.

ROBERTSHAW 220R GAS

CONTROL/

GAS CONTROL

KNOB

 

RÉGULATEUR DE GAZ

SHOWN IN “OFF” POSITION

 

 

 

 

 

 

ROBERTSHAW 220R

 

 

 

 

PRESSURE REGULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITER

 

 

 

 

 

 

 

 

 

 

 

PILOT

THERMOCOUPLE

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE

TEMPERATURE DIAL

 

4.Turn gas control knob clockwise to the “OFF” position.

5. To clear any gas that may have accumulated wait ten (10) minutes. If you then smell gas, STOP! Follow instruction “B” described above.

6. Turn the gas control knob counterclockwise to“PILOT”.

7. Depress the gas control knob all the way in and

IMMEDIATELY depress the igniter button until you hear a loud click. Observe the pilot through the view port. Do not release the knob. Repeat immediately if pilot does not light on the first try. If the pilot does not light by the fourth attempt with the igniter, repeat steps 3-6. Continue to hold the control knob for about (1) minute after the pilot is lit. Release the control knob and it will pop back up. Pilot should remain lit. If the pilot light goes out, repeat steps 3-7.

IMPORTANT: If the pilot will not stay lit after several tries, turn gas control knob to “OFF” and call your service tech- nician or gas supplier.

IMPORTANT: If the gas control knob does not pop up to its original position when released, stop and immediately shut off the gas at the line valve or tank. Call your service technician or gas supplier.

8. Turn the gas control knob counterclockwise to “ON”.

9.Set the temperature dial to the desired setting. 10.Replace the outer door.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting. Turn counterclockwise.

2.Turn the gas control knob “OFF”. Rotate clockwise.

– 16 –

Image 16
Contents For Your Safety What to do if YOU Smell GASPage IX Repair Parts Illustration Viii Troubleshooting GuideLimited Warranty Introduction II Safety For Installations in CanadaFor Installations in the United States User ResponsibilitiesSafety Warning Flammable Vapours Safety Warning ScaldingSafety Warning Carbon Monoxide Backflow PreventionLocation Requirements Clearances and AccessibilityEarthquake Zones Gas Supply Failure to Properly Install this Heater MAYResult in a Fire Hazard Gas Pressure Gas Leak TestingGas line purging Air Requirements Confined Space Air Requirements for Canadian InstallationsLocal Codes Confined Space Air Requirements for Installations Exhaust Venting Water SupplyValve is dripping or leaking, have a Licensed plumber repair itDo not plug valve Do not remove valveTemperature And Pressure Relief Valve Installations CheckDischarge Line IV Operating Instructions Water Temperature Regulation Temperature AdjustmentLighting Instructions Robertshaw 110R What to do if YOU Smell GASLighting Instructions Robertshaw 220R Lighting Instructions White-Rodgers 37C AvantOperation Burner Flames Emergency Shut DownChecking the Draft Operating ConditionsDraining and Flushing VI MaintenancePeriodic Inspection Resetting and Replacing the Safety TCO Switch External Cleaning Flame-arresterTemperature and Pressure Relief Valve VII Combo Heating System RequirementsViii Troubleshooting Guide Problem Possible Causes CorrectionThermostat Fails to Shut IX Repair Parts Illustration Repair PartsLimited Warranty WHO is CoveredHOW the Original Owner can Make a Warranty Claim

72090 specifications

The GSW 72090 is a remarkable addition to the world of modern heating solutions, designed to provide efficient and effective space heating. It epitomizes advanced technology, reliability, and user-centric design, making it an ideal choice for homes and commercial spaces alike.

One of the main features of the GSW 72090 is its impressive heating capacity. Engineered to deliver optimal warmth, it can efficiently heat larger areas, ensuring that spaces remain comfortable even during the coldest months. The unit’s high-grade alloy construction enhances durability and helps maintain consistent performance over time.

A vital technology integrated into the GSW 72090 is its modulating control system. This system intelligently adjusts the temperature output based on the current heating demand, optimizing energy usage and contributing to lower utility bills. This efficiency not only benefits the consumer but also has a positive impact on the environment by reducing greenhouse gas emissions.

The GSW 72090 also boasts a sleek and modern aesthetic, making it an attractive addition to any space. Its design allows for easy installation and maintenance, ensuring that users can focus on comfort without worrying about the complexities of upkeep. The unit operates quietly, providing a peaceful environment without the disruptive noises often associated with traditional heating systems.

Incorporating safety features is another key characteristic of the GSW 72090. It includes overheat protection, which automatically turns the unit off if it detects excessive temperatures, ensuring a safe environment for occupants. Additionally, the product is constructed with materials that are resistant to corrosion and wear, enhancing longevity.

As an environmentally conscious option, the GSW 72090 is designed to comply with stringent energy efficiency regulations. Its performance not only meets but often exceeds the required standards, making it a smart choice for those looking to reduce their carbon footprint.

Overall, the GSW 72090 stands out due to its combination of advanced technologies, user-friendly features, aesthetic appeal, and commitment to safety and efficiency. Its multi-faceted capabilities make it a prime option for anyone seeking reliable and effective heating solutions in their home or business.