Drainage
Prepare for drainage and drain out water within the unit in the following cases
If the unit stops operating and the TIMER and OPERATION lamps and are blinking, this indicates that the water tank inside the unit is full.
1.Make sure to turn the unit off.
2.Turn the drainage nozzle to the OPEN position.
Drainage nozzle
Stopcock (Upper)
“OPEN position”
3.Pull the stopcock (upper) out from the drainage nozzle.
•When the stopcock (upper) is removed, a small amount of water may be discharged from the drainage nozzle.
4.Insert the hose clamp onto the drain hose.
5.Attach the drain hose to the drainage nozzle, and secure it with the hose clamp.
•Prepare for draining, as drain water will come out through the drain hose during operation.
Hose clamp
Drain hose
6.Press the MANUAL button on the unit twice.
•The water will drain out through the drain hose. Maximum amount of water that may be drained out is approximately 2 litres.
•The OPERATION and TIMER cool lamps will be blinking.
7.When drainage water stops running out from the drain hose, turn the unit off by pressing MANUAL button.
•This should take about one minute to complete.
8.Remove the drain hose from the drainage nozzle, and replace the stopcock (upper).
•Keep the hose clamp for future use.
9.Turn the drainage nozzle to the CLOSE position.
electrolux EXP09CS1WI drainage 19
Whenever the unit is moved (to prevent water within the unit from spilling).
When the unit is not going to be used for a long time
1.Carry out the previous procedures from 1 to 5.
2.Press the MANUAL button on the unit.
•The water will drain out through the drain hose. Maximum amount of water that may be drained out is approximately 2 litres.
•The OPERATION lamps will illuminate.
3.When drainage water stops running out from the drain hose, turn the unit off by pressing the MANUAL button.
•This should take about one minute to complete.
4.Remove the drain hose from the drainage nozzle, and replace the stopcock (upper).
•Keep the hose clamp for future use.
5.Turn the drainage nozzle to the CLOSE position.
6.Remove the stopcock (lower) from the drainpipe nozzle, and completely drain any water within the unit.
•Always prepare a receptacle to collect the water before draining. Maximum amount of water that may be drained out is approximately 0.2 litres.
7.Replace the stopcock (lower) to the drainpipe nozzle.