840115900 ENv00.qxd 6/6/03 9:03 AM Page 15
Replacing the UV Bulb
The UV bulb is designed to provide approximately one year of continuous, effective operation. After this time, the bulb may remain illuminated, but its effectiveness is greatly reduced.
For maximum germicidal protection, replace the UV bulb when replacing the HEPA filter, or if the UV bulb
To Remove the UV Bulb:
1
2
check window does not glow when the UV switch is on. The UV replace- ment bulb cannot be purchased in stores. Replacement bulbs may be available where the air purifier was purchased or can be obtained directly from Hamilton Beach.
Turn off and unplug the air purifier. Open and remove the outlet grille by pulling upon the handle on the upper back of the air purifier.
Gently rotate the bulb a quarter turn in either direction until it unlocks from the socket. Pull the pins out the sides of the socket, one end at a time.
To Install the New UV Bulb:
Refer to steps 3 through 6 on pages 8 and 9 to install the new UV bulb. Be sure to discard the old UV bulb in a safe and responsible manner in accordance with any applicable local, state, and federal regulations.
If the UV bulb check window still does not glow, replace the starter.
Remember, oils from fingertips will shorten the life of the bulb. Do not touch the glass part of the bulb.
15