Sierra Monitor Corporation 2-Wire Series Model 4501-XXToxic Gas Sensor Module, Page, Key Function

Page 18
6.3 DIAGNOSTICS SUB-MENU

 

 

 

 

 

 

Model 4501-XX Toxic Gas Sensor Module

 

6.3 DIAGNOSTICS SUB-MENU

 

 

 

 

 

 

 

 

 

 

 

Key Function

Display
Description
Reference

 

M

E

Mode

H2S

 

Default Display (example 4501-05)

or Sub-Routine A

 

S

T

CALIB:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

E

Enter

CAL 0 PPM

 

Banner: Apply zero gas, [E] when done

 

 

S

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation: Confirm area clear of gas, or apply zero air to sensor.

 

 

 

 

 

 

 

 

 

 

M

E

Enter

Cal0PPM

 

There is a minimum time to calibrate at 0PPM. If [E] is hit prior to this time

 

 

S

T

Wait.XXX

 

has elapsed, a countdown screen will appear.

 

 

 

 

 

ZERO

 

Zero gas setting completed (Message will appear on the screen and after 3

 

 

 

 

 

DONE

 

seconds will go to the next menu - 25PPM Span)

 

 

 

 

 

XXPPM

 

Banner: [S] or [T] to change span value, [E] when done

Sub-Routine B

 

 

 

 

 

 

 

 

 

 

 

 

H2S

 

Operation: 148 second time out before sensor is returned to service.

 

 

 

 

 

WAIT-148

 

 

 

 

 

 

 

 

 

 

M

E

Enter

H2S

 

Banner: Remove gas from sensor

Sub-Routine C

 

S

T

CAL-OK

 

 

 

 

 

 

 

Sub-Routine A - Abort Calibration

 

 

 

 

 

 

 

 

 

 

M

E

Mode

CALIB

 

Operation: Hold magnet over [M] for 10 seconds to abort calibration

 

 

S

T

ABORTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H2S

 

Default Display

 

 

 

 

 

XXX PPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub-Routine B - Select Span

 

 

 

 

 

 

 

 

 

 

 

25PPM SPAN

Banner: [S] or [T] to change span value, [E] when done

 

 

 

 

 

 

 

 

 

M

E

Down

C##PPM

 

Banner: Apply xx-PPM gas, [E] when stable

Should be stable after 3

 

S

T

 

minutes of gas exposure

 

M

E

Enter

H2S

 

Operation: Remove gas from sensor

If calibration failed, then

 

S

T

REMOVE GAS

 

Sub-Routine C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H2S

 

Calibration successful

 

 

 

 

 

CAL-OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub-Routine C - Calibration Fail

 

 

 

 

 

 

 

 

 

 

M

E

Enter

READ

 

Operation: Remove gas from sensor read manual, particularly section 6.3 and

 

 

S

T

MANUAL

 

7.6, to check calibration procedures.

 

 

 

 

 

H2S

 

Calibration Failed

 

 

 

 

 

CAL-FAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 6-1

 

 

 

 

 

 

 

Calibration Sub-Menu

 

Page: 14

Image 18
Contents 2-WireSeries APPLICABILITY & EFFECTIVITY4501-05FM Approved 4501-06FM Pending MODELModel 4501-05Hydrogen Sulfide Gas Sensor Module Model 4501-XXToxic Gas Sensor ModuleFM PERFORMANCE APPROVAL Sensor ModuleContents Model 4501-XXToxic Gas Sensor ModuleContents CABLING INSTALLATIONModel 4501-XXToxic Gas Sensor Module 1. PRODUCT DESCRIPTION PageModel 4501-XXToxic Gas Sensor Module 1.6POWER REQUIREMENTS 1.4.3SENSOR ASSEMBLY1.5INTERCONNECT WIRING Model 4501-XXToxic Gas Sensor ModuleModel 4501-XXToxic Gas Sensor Module Page2. CAUTIONS & WARNINGS Model 4501-XXToxic Gas Sensor ModulePage 3. QUICK START Model 4501-XXToxic Gas Sensor ModulePage Model 4501-XXToxic Gas Sensor Module 4. INSTALLATIONFigure 4-20mA Connection PageFigure Connector Locations Page Model 4501-XXToxic Gas Sensor ModuleFigure Face Plate with Operator Keypad Page 5. OPERATIONKey ENTER Model 4501-XXToxic Gas Sensor ModuleDescription FunctionDisplay ReferenceFunction Model 4501-XXToxic Gas Sensor ModuleSub-RoutineA DisplayModel 4501-XXToxic Gas Sensor Module 5.5DIAGNOSTICS SUB-MENUDiagnostics Sub Menu PageModel 4501-XXToxic Gas Sensor Module PageModel CALIBRATION PROCEDURE6. CALIBRATION FlowPage 6.3 DIAGNOSTICS SUB-MENUModel 4501-XXToxic Gas Sensor Module Key FunctionENCLOSURE REPLACEMENT 7. SERVICE7.1SENSOR MODULE CONFIGURATION Figure Module Components PageINSTALLATION INSPECTION TRANSMITTER REPLACEMENTSENSOR REPLACEMENT Model 4501-XXToxic Gas Sensor ModuleWiring terminations clean and correct Model 4501-XXToxic Gas Sensor ModulePage 8. APPENDICES SpecificationsAPPENDIX A SPECIFICATIONS Model 4501-XXToxic Gas Sensor ModuleModel 4501-XXToxic Gas Sensor Module WarrantyLimited warranty PagePage APPENDIX B MODEL NUMBERS & PARTS LISTModel 4501-XXToxic Gas Sensor Module Sensor ModuleAPPENDIX C LIMITED WARRANTY Model 4501-XXToxic Gas Sensor ModulePage