Model
3. QUICK START
3.1OVERVIEW
The gas sensor module has been supplied factory calibrated and ready for immediate installation and operation. An installer familiar with installation and operation of gas detection products can use this section to begin immediate use of the module.
3.2WIRING
Provide two conductor shielded wiring from the power supply/control device to the sensor module location. Use wire that is 16 AWG or larger.
3.3MODULE INSTALLATION
The
The module is designed to be installed on a ¾” conduit. Two important warnings:
•The installation must meet any hazardous environment codes for electrical equipment
•The sensor module enclosure mounting must be spaced far enough from any vertical surface to allow removal and replacement of the sensor assembly which is threaded into one ¾” conduit entry.
3.4TRANSMITTER INSTALLATION
To install the transmitter printed circuit assembly into the housing, carefully turn the faceplate so that the printing is in the correct horizontal position for the mounting configuration and slide the assembly over the two
Hand tighten the two captive panel thumb screws into the
•If the transmitter is installed in a classified hazardous area, replace the threaded cover prior to providing power.
3.5
To begin operation of the sensor module activate the instrument loop with
After the
3.6ZERO STABILIZATION
All electrochemical sensors require at least 30 minutes on power prior to calibration. This allows the electrode potentials to equilibrate, resulting in a stable zero signal level.
Page: 5