Smith Cast Iron Boilers GVIOM-5R manual North ELM Street WESTFIELD, MA 01085 TEL 562-9631 FAX 413

Page 24

WARNING

Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of producing carbon monoxide (CO).

Carbon monoxide (CO) is a gas which is odorless, colorless and tasteless but is very toxic.

If your Smith boiler is not working properly, or is not vented properly, dangerous levels of CO may accumulate. CO is lighter than air and thus may travel throughout the building. Brief exposure to high concentrations of CO, or prolonged exposure to lesser amounts of CO, may result in carbon monoxide poisoning.

Exposure can be fatal and exposure to high concentrations may result in the sudden onset of symptoms including unconscious- ness.

Symptoms of CO poisoning include:

 

 

dizziness

vision problems

shortness of breath

headaches

loss of muscle control

unclear thinking

nausea

weakness

unconsciousness

The symptoms of CO poisoning are often confused with those of influenza, and the highest incidence of poisoning occurs at the onset of cold weather or during flu season. A victim may not experience any symptoms, only one symptom or a few symptoms. Suspect the presence of carbon monoxide if symptoms tend to disappear when you leave your home.

The following signs may indicate the presence of carbon monoxide:

Hot gases from appliance, venting system, pipes, or chimney escaping into the living space.

Flames coming out around the appliance.

Yellow colored flames in the appliance.

Stale or smelly air.

The presence of soot or carbon in or around the appliance.

Very high unexplained humidity inside the building.

If any of the symptoms CO poisoning occur, or if any of the signs of carbon monoxide are present, vacate the premises imme- diately and contact a qualfied heating service company, the gas company or the fire department.

To reduce the risk of CO poisoning, have your heating system “tuned up” by a licensed heating contractor or the gas company - preferably before each heating season. Also have the service company check your chimney or vent pipes for blockage.Your home should also be adequately ventilated, particularly if you have insulated your home.

ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR SMITH BOILER.

WARNING

Install, operate and maintain unit in accordance with manufacturer’s instructions to avoid exposure to fuel substances or sub- stances from incomplete combustion which can cause death or serious illness. The State of California has determined that these substances may cause cancer, birth defects, or other reproductive harm. Also, install and service this product to avoid exposure to airborne particles of glasswool fibers and/or ceramic fibers known to the State of California to cause cancer through inhalation.

WESTCAST, INC.

260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799

Image 24
Contents GV100W GV100W Boiler Installation & Operating Instructions Boiler Ratings & Capacities Boiler LocationCombustible Floor Option Boiler Dimensions Fresh Air ⁄4 Wire Metal Wooden Duct Size Combustion AIRCommon Vent Systems Combustion Air Duct SizingChimney Venting Chimney Inspection & SizingVertical Venting Horizontal Venting Heating System PipingNo B System Bypass Pump Away BypassPumped Blend Piping For Use With Cooling UnitsReverse Acting Aquastats GAS Supply Piping CirculatorsElectrical Wiring Thermostat InstallationEquivalent Pipe Length Chart CO DetectorsFIG. no Fenwal/Honeywell Hot Surface Ignition FIG. no Multi-Zone Diagram For Your Safety Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance Property damage, personal injury or loss of lifePour Votre Sécurité Lisez Avant DE Mettre EN Marche Boiler SET-UP Boiler OperationDirect Ignition Systems Checking & Adjustment Boiler Maintenance Burner InstallationHeat Exchanger Cleaning Burner RemovalInstructions to the Installer GV100 Series Repair Parts Name of PartRef # Name of Part HSI Fenwall Ignition SystemNorth ELM Street WESTFIELD, MA 01085 TEL 562-9631 FAX 413

GVIOM-5R specifications

The Smith Cast Iron Boilers GVIOM-5R is a high-efficiency, versatile heating solution designed for both residential and commercial applications. This model is particularly renowned for its robust construction, impressive performance, and energy-saving features. With a focus on durability, the GVIOM-5R is built from high-quality cast iron, which not only ensures longevity but also excellent thermal mass for effective heat retention.

One of the main features of the GVIOM-5R is its fire-tube design, which enhances heat transfer and allows for higher efficiency rates compared to traditional boiler designs. The fire-tube configuration ensures that flue gases travel through a series of tubes submerged in water, maximizing heat exchange and minimizing heat loss. This design contributes to an efficiency rating that often exceeds 85%, helping users to reduce their energy costs while maintaining comfort.

The boiler is equipped with advanced control technology, allowing for precise temperature management. This feature is critical for optimizing performance and ensuring consistent heating throughout the property. Additionally, an integrated diagnostic system enables users to monitor boiler operations and troubleshoot potential issues before they escalate, ensuring reliable performance and reducing downtime.

Another characteristic that sets the GVIOM-5R apart is its flexibility in fuel options. The boiler can operate on various fuels, including natural gas, propane, or oil, making it an adaptable choice for different heating needs. This multi-fuel capability not only provides versatility but also allows property owners to choose the most economical and efficient fuel source based on their specific circumstances.

Maintenance is also simplified with the GVIOM-5R, thanks to its accessible design that allows for easy servicing and parts replacement. The robust construction minimizes the need for frequent repairs, which enhances overall reliability and customer satisfaction.

In summary, the Smith Cast Iron Boilers GVIOM-5R combines durability, efficiency, and versatility. Its innovative fire-tube design, advanced control systems, multi-fuel capabilities, and ease of maintenance make it an outstanding choice for those seeking a reliable heating solution. Whether for a home or a commercial building, the GVIOM-5R stands out as a top-tier option that delivers consistent performance and long-term value.