Clean unit and accessories
Put floor nozzle on
Fill
Switch on “spray” button and let the unit and accessories rinse thoroughly for approx.
Switch unit off and pull the power plug out of the socket.
Operate valve handle in the floor nozzle, in this way pressure in the system is removed.
Pull out
Empty
Clean unit.
The floor nozzle can be locked in the carrying handle for storage purposes or for transporting the unit (Fig. 12).
Care and Maintenance
Caution:
Before any maintenance work takes place, pull the power plug out of the socket.
Check mains cable, connection cable and hoses for damage before putting the unit into operation for the first time.
Before longer periods of disuse, the entire water must be drained out of the unit otherwise unpleasant odours might occur.
From time to time clean the suction strainer in the
Troubleshooting
Caution:
Danger from electrical current. Pull out power plug before any work is carried out on electrical parts.
No water coming out at the nozzle
1.
2.Check that the position of the coupling of the spray and suction hose is correct.
3.Nozzle blocked, clean it.
4.Suction filter in fresh water tank blocked, clean it.
5.Spray pump defective, have it replaced by a technical expert.
Spray emitted from one side only
1. Nozzle is partly blocked, clean it.
Insufficient suction power
1.Cover not on properly, put it on properly
2.Seal on cover dirty, clean it.
3.Fluff strainer dirty, clean it.
4.Suction hose is blocked, check and clean it.
Spray pump too loud
1.
Have all inspections and work carried out on electrical parts done by a technical expert. For more extensive tasks contact customer service.