Nighthawk KN-COEG-3 Part Six Frequently Asked Questions, What happens if the power goes out?

Page 19

Part Six – Frequently Asked Questions

Q.How many alarms do I need in my house? How much square footage will one alarm cover?

A.We recommend you place alarms near the sleeping area(s). If you have a multi-level home, you should place an alarm on each level of the home. A good rule of thumb for the number and placement of CO and Gas alarms for your particular home is to place CO and Gas alarms near smoke alarms that have been installed to meet current building code requirements.

Generally, one alarm can be adequate for 1,200 to 1,500 square feet of living space. The most important determination for the number of units needed is whether an alarm can be heard in all sleeping areas.

Q. Can you explain what “time-weighted alarm” means? A. Because carbon monoxide is a cumulative poison, two factors determine how the body is affected by CO: the level of exposure and the length of exposure. For example, being continuously exposed to low levels of carbon monoxide for many hours can be as dangerous as being exposed to higher levels of CO for a short period of time.

The microchip inside your Nighthawk CO and Gas alarm moni- tors the air for the presence of carbon monoxide and computes the levels and length of exposure, alarming when you should be concerned about CO exposure.

For more information about the alarm, see page 5-1.

Q. Do I have to press the test button to get a CO or Gas reading?

A. No. Your Nighthawk CO and Gas alarm continuously moni- tors the air for carbon monoxide and gas. An updated reading is shown on the digital display every 15 seconds. If there is no CO or Gas present, the digital display will show a zero. The alarm will alert you to the presence of CO or Gas automatically.

To test the internal components and circuitry of your alarm, press the Test/Reset button. For complete instructions on testing your alarm, see page 1-5,6.

Q.What happens if the power goes out?

A. If a good battery is in the unit, the alarm will display a blink- ing dot for at least 20 hours while still providing protection against CO or Gas exposure. Please note however, that the alarm will sample for the presence of gas once every eight minutes while on battery backup. Gas could be present during this eight minute period without alarming. Please see page 1-5.

Q.How do I get the alarm to show something besides “0.” OR, How can I determine if the sensors are operating correctly?

A.Please refer to “Testing Sensor Response” on page 1-6 for com- plete instructions on how to test your alarm’s electronics and sen- sor functions.

Q.You warranty the alarm for five years. How will I know when it doesn’t work anymore and I need to buy a new one?

A.In any event of malfunction, your alarm will alert you with malfunction signals. These signals are described in detail on page 1-6.

Q.What do the numbers mean on the digital display when

Ipress the “Test/Reset” button?

A.The numbers you see when you press the Test/Reset button are NOT a CO reading or a Gas alarm. This is a simulated read- ing the alarm displays as it tests its electronics. The numbers dis- played when the Test/Reset button is pushed should be between 100 to 400 (usually around 200). These numbers are shown after the “Gas” test is complete.

Q.I called in someone to inspect my home for CO after my unit alarmed, and he couldn’t find anything wrong. Why? Does that mean this unit “false alarmed”?

A.No. Please read the information explaining why a CO prob- lem can be difficult to diagnose on page 4-2. Also, please read the information on page 1-6 to make sure you experienced an alarm and not a malfunction alert.

Q.I tried to test the alarm (see below) and it still reads “0.” Why?

by running the car in the garage

by holding it to the tailpipe of the car

by putting it next to the furnace vent

A.DO NOT try to test your alarm by doing any of the above! Testing the alarm using any of the methods listed above usually does not yield satisfactory results and could in fact be dangerous. To accurately test the alarm, please follow the guidelines given on page 1-5,6.

Never operate a vehicle in a closed garage, as high levels of CO can be built up in a short time. With an attached garage, dan- gerous CO levels develop inside the home as well as within the garage.

6-1

Image 19
Contents Carbon Monoxide and Explosive Gas Alarm Table of Contents Introduction About this User’s GuideQuick Set-Up Guide Setting up your CO and Gas alarm for first time operationAbout Your CO and Gas Alarm Part One Your Nighthawk CO and Gas AlarmDigital Display Nighthawk’s Unique FeaturesWhere Not to Install Your CO and Gas Alarm Where to Install Your CO and Gas AlarmTo rotate adapter How to Install Your AlarmDirect Plug Alarm To installNormal Operating Characteristics Wall Mounted AlarmTable Top Alarm Testing the Electronics How to Test Your AlarmTesting the sensor response Malfunction Signal Group 2 Microprocessor Failure If the alarm malfunctionsMalfunction Signal Group 1 Component Failure Low Battery WarningPeak Level Memory Button How to Know If Your Alarm is MalfunctioningHow to Care for Your Alarm To Reset the Peak Level Memory…Part Two Carbon Monoxide and Gas What You Should Not Do Home Safety Tips What You Can DoClues You Cannot See Mid Levels Part Three What You Should Know Before the Alarm SoundsHigh Levels Common Medium Exposure Symptoms Common Mild Exposure SymptomsCommon Extreme Exposure Symptoms Treatment for CO Poisoning Part Four What to Do if the Alarm Sounds for GasWhat to do if the Alarm Sounds for Gas Do not activate any electrical switch or telephonePart Five Technical Information What happens if the power goes out? Part Six Frequently Asked QuestionsPart Six Frequently Asked Questions Part Six Display Reading and What They Mean Display Shows Alarm Sound Unit StatusDisplay Shows Alarm Sound Unit Status Recommended Action Readings You May See When Unit is AC PoweredPage Wall Mount Diagram Warranty Registration Limited WarrantyPlease send products and all other correspondence to

KN-COEG-3 specifications

The Nighthawk KN-COEG-3 is a state-of-the-art carbon monoxide and explosive gas detector designed to offer paramount safety for homes and workplaces. With its sleek design and advanced technology, this device stands out in the market for its reliability and ease of use. One of the most striking features of the KN-COEG-3 is its dual-function capability, allowing it to detect both carbon monoxide (CO) emitted from sources like gas appliances and vehicles and explosive gases such as natural gas and propane. This dual detection provides an added layer of safety, ensuring that you are alerted to potential dangers in real time.

The device is equipped with a highly sensitive electrochemical sensor for carbon monoxide detection, which offers precise readings and minimizes false alarms. The explosive gas sensor utilizes a catalytic bead technology, which allows for quick identification of dangerous gas leaks. Together, these technologies ensure that you are protected from two of the most serious gas-related hazards.

Another key feature of the Nighthawk KN-COEG-3 is its user-friendly interface. The device includes a well-designed LCD display that provides clear, easy-to-read information regarding the levels of carbon monoxide and explosive gases detected in the air. It also features a loud alarm system that activates immediately upon detection of dangerous levels, ensuring that occupants can promptly respond to evacuation protocols.

The KN-COEG-3 boasts a compact and stylish design, making it easy to install in various locations, whether mounted on a wall or placed on a countertop. It is powered by an AC adapter with a battery backup, which guarantees continuous operation even in the event of a power outage. This reliability ensures peace of mind for users, whether they are at home or away.

Additionally, the device incorporates advanced self-test features that allow it to periodically check its sensor and system functionality, assuring users of its operational integrity. By coupling advanced technology with a commitment to user safety, the Nighthawk KN-COEG-3 presents a compelling solution for anyone looking to enhance their safety against carbon monoxide and explosive gas hazards in their environment.