Beckett CF1000 manual ‰ Install nozzle line assembly, ‰ Set dimension Z

Page 9

Figure 4 - Nozzle and nozzle line assembly

Critical dimensions -

P

(Electrode spacing)

= 3/32”

R

Nozzle center line to electrode tip) = 1/4”

Q

(Nozzle to head) =

1/4”

S

Nozzle face to electrode tip = 1/8”

Figure 5 - Nozzle line assembly in burner

Measure dimension Z from front (flat) face of head to end of air tube, as shown.

Measure dimension Z from the

flat surface between (not on) the Z = 1-3/4” ± 1/16” raised fins.

Legend (Figures 5 and 6)

cBottom acorn nut

dTop acorn nut (for setting dim. Z only

eIndicator adjusting plate f Secondary adjusting plate

gPrimary adjusting plate

‰Install nozzle line assembly

yInsert the nozzle line assembly into the burner air tube as in Figure 5.

ySee Figures 5 and 6. Assemble the adjusting plate assem- bly per the instructions in the assembly packet.

ySlide the secondary adjusting plate (item f) completely to the left on the indicator adjusting plate (item e). Finger tighten acorn nut c to secure the two plates together. Slide both plates completely to the left on the primary adjusting plate (item g) and finger-tighten acorn nut d.

ySlide the completed adjusting plate assembly over the noz- zle line end. Move the plate assembly and the nozzle line so the plate assembly fits into position as shown in Figure 5.

yInstall the spline nut (Figure 5, item b) on the end of the nozzle line, leaving the nut loosely placed so the plates can be moved.

yConnect the high-voltage leads from the ignition trans- former to the electrodes.

Figure 6 - Adjusting plate assy.

‰Set dimension Z

yReplace the rear access door on the burner, making sure that the adjusting plate assembly is now securely in the groove.

yLoosen acorn nut d in Figure 5. Slide the nozzle line and plate assembly until dimension Z in Figure 5 is 1-3/4” ± 1/16”. When dimension Z (from end of air tube to flat area of front face of head) is correctly set, tighten acorn nut d. Verify that the adjusting plate assembly is properly seated in the adjusting groove.

yAttach the oil line from the oil valve to the nozzle line end. Tighten securely.

yBefore proceeding, check dimension Z once again. Loosen acorn nut d if necessary to reposition the nozzle line. Once dimension Z is set, do not loosen acorn nut d again. For the setting of acorn nut c, refer to Page 13.

Form 6104 BCF10-R06

9

Image 9
Contents To the Professional, Qualified Installer or Service Agency Potential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner Form 6104 BCF10-R06 Table of Contents Indicates an imminently Hazardous situation Specifications Agency approvalsProtect Against Stray Light Lockout Follow These Instructions ExactlyProtect Against Dust Moisture Adequate Combustion Ventilation Air Supply RequiredCorrect Nozzle and Flow Rate Required Oil Supply Pressure Con- trol Required‰ Electrical supply ‰ Vent system‰ Verify burner components ‰ Verify firing rateProtect the Air Tube From Overheating ‰ Install nozzle‰ Mount flanges on air tube ‰ Mount air tube to burner‰ Set dimension Z ‰ Install nozzle line assembly‰ Insert burner Do Not Install By-pass Plug with 1-Pipe System‰ Fuel unit by-pass plug ‰ Oil supply/return lines‰ Burner fuel flow Install Oil Supply To SpecificationsProfessional Installation Service Required Do Not Bypass Safety ControlsKeep Service Access Cov- ers Securely Installed Electrical Shock HazardSequence of Operation typical ‰ Z dimension‰ Adjusting plate assembly Figure ‰ Initial air settings Figure‰ Initial head position Figure Hot Gas Puff-back Heavy Smoke Hazard Explosion and Fire Hazard‰ Set appliance limit controls ‰ Prepare the fuel unit for air venting‰ Set air adjusting plate Figure Annual Professional Service Required Monthly maintenance by ownerAnnual service by qualified service techni- cian Replacement parts Form 6104 BCF10-R06 Warranty

CF1000 specifications

The Beckett CF1000 is a cutting-edge, reliable, and efficient commercial burner designed for use in various heating applications. Known for its exceptional performance, it is increasingly popular among businesses and contractors looking for an effective solution to meet their heating needs.

One of the main features of the CF1000 is its advanced combustion technology. The burner is engineered to deliver optimal combustion efficiency, reducing emissions and enhancing fuel economy. This technology not only helps in lowering operational costs but also aligns with modern environmental regulations, making the CF1000 a responsible choice for energy-conscious businesses.

Another notable characteristic of the CF1000 is its ability to handle multiple fuel types, including oil and natural gas. This versatility allows users to choose the best fuel source for their specific application, contributing to operational flexibility. Additionally, the CF1000 is equipped with a modulation system that adjusts the burner output in response to demand, ensuring consistent heating without unnecessary energy consumption.

The CF1000 also stands out for its compact design, making it easy to install in various settings, whether in commercial buildings or industrial facilities. Its robust construction is designed to withstand demanding conditions, ensuring longevity and reliability. Moreover, the burner comes with advanced safety features, including flame monitoring and integrated shut-off systems, helping to prevent potential hazards during operation.

Ease of maintenance is another significant advantage of the Beckett CF1000. The design incorporates user-friendly service access points, allowing technicians to perform routine maintenance and inspections quickly and efficiently. This not only ensures optimal performance but also extends the lifespan of the burner.

Furthermore, the CF1000 is supported by Beckett's extensive customer service and technical support. Their commitment to quality and satisfaction means that users can rely on expert assistance whenever needed, ensuring peace of mind.

Overall, the Beckett CF1000 is a premier choice for those seeking a high-performance commercial burner. With its advanced combustion technology, versatile fuel options, compact design, and a wealth of safety features, it delivers reliable heating solutions suitable for a wide range of applications. Its ease of maintenance combined with robust support services makes the CF1000 an intelligent investment for any business prioritizing efficiency, safety, and reliability in their heating systems.