Beckett CF1000 manual Replacement parts

Page 18

Replacement parts

Item

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

Part Name

Timer

Oil Valve

Adjusting plate assembly Knurled nut

Fuel pump

Pedestal kit

Fuel lines

Damper spring

Sight glass

Rear cover door assembly Control

Damper indicator

Coupling Hole Plug

Coupling Access Door

Head assembly

Electrode assembly

Ignition leads

Nozzle line assembly

Air tube

Transformer

Coupling

Blower wheel

Motor

Motor relay (not shown)

Adjustable flange

Description

Nozzle valve delay

Box mounted

CF10-2300 Kit

All models

B2TA-8245

H3PAN-C150H

All models

Specify length

All models

All models

Cast aluminum door* Stamped sheet-metal door*

Specify

All models

Use with threaded hole

Use with rectangular opening

CF1000 combustion

All models

8-1/4” long

11-3/4” long

15-1/4” long

19-1/4” long

Refer to Figure 2, Page 7

Refer to Figure 2, Page 7

12,000 volt

Bpump H pump

CF1000 5.50” x 3.09”

120/208-230V single phase 208/230-460V three phase

120V single phase

208V single phase three phase

see Figure 13 on opposite page

Part Number

21295U

21789U

51213U

3666

21313U

21309U

51193

-

4339

31346

5994U

5201301U

-

5985BK

32439U

16703GY

51203P

51212

5990082

5990116

5990152

5990192

51214

21290

21308

21268U

21401U

21638U

7273

7300

21719

* These doors are NOT interchangeable. Please specify what you are replacing.

18

Form 6104 BCF10-R06

Image 18
Contents To the Professional, Qualified Installer or Service Agency Potential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner Form 6104 BCF10-R06 Table of Contents Agency approvals Indicates an imminently Hazardous situation SpecificationsProtect Against Dust Moisture Follow These Instructions ExactlyProtect Against Stray Light Lockout Adequate Combustion Ventilation Air Supply RequiredOil Supply Pressure Con- trol Required Correct Nozzle and Flow Rate Required‰ Verify burner components ‰ Vent system‰ Electrical supply ‰ Verify firing rate‰ Mount flanges on air tube ‰ Install nozzleProtect the Air Tube From Overheating ‰ Mount air tube to burner‰ Install nozzle line assembly ‰ Set dimension Z‰ Fuel unit by-pass plug Do Not Install By-pass Plug with 1-Pipe System‰ Insert burner ‰ Oil supply/return linesInstall Oil Supply To Specifications ‰ Burner fuel flowKeep Service Access Cov- ers Securely Installed Do Not Bypass Safety ControlsProfessional Installation Service Required Electrical Shock Hazard‰ Z dimension Sequence of Operation typical‰ Adjusting plate assembly Figure ‰ Initial air settings Figure‰ Initial head position Figure ‰ Set appliance limit controls Explosion and Fire HazardHot Gas Puff-back Heavy Smoke Hazard ‰ Prepare the fuel unit for air venting‰ Set air adjusting plate Figure Annual Professional Service Required Monthly maintenance by ownerAnnual service by qualified service techni- cian Replacement parts Form 6104 BCF10-R06 Warranty

CF1000 specifications

The Beckett CF1000 is a cutting-edge, reliable, and efficient commercial burner designed for use in various heating applications. Known for its exceptional performance, it is increasingly popular among businesses and contractors looking for an effective solution to meet their heating needs.

One of the main features of the CF1000 is its advanced combustion technology. The burner is engineered to deliver optimal combustion efficiency, reducing emissions and enhancing fuel economy. This technology not only helps in lowering operational costs but also aligns with modern environmental regulations, making the CF1000 a responsible choice for energy-conscious businesses.

Another notable characteristic of the CF1000 is its ability to handle multiple fuel types, including oil and natural gas. This versatility allows users to choose the best fuel source for their specific application, contributing to operational flexibility. Additionally, the CF1000 is equipped with a modulation system that adjusts the burner output in response to demand, ensuring consistent heating without unnecessary energy consumption.

The CF1000 also stands out for its compact design, making it easy to install in various settings, whether in commercial buildings or industrial facilities. Its robust construction is designed to withstand demanding conditions, ensuring longevity and reliability. Moreover, the burner comes with advanced safety features, including flame monitoring and integrated shut-off systems, helping to prevent potential hazards during operation.

Ease of maintenance is another significant advantage of the Beckett CF1000. The design incorporates user-friendly service access points, allowing technicians to perform routine maintenance and inspections quickly and efficiently. This not only ensures optimal performance but also extends the lifespan of the burner.

Furthermore, the CF1000 is supported by Beckett's extensive customer service and technical support. Their commitment to quality and satisfaction means that users can rely on expert assistance whenever needed, ensuring peace of mind.

Overall, the Beckett CF1000 is a premier choice for those seeking a high-performance commercial burner. With its advanced combustion technology, versatile fuel options, compact design, and a wealth of safety features, it delivers reliable heating solutions suitable for a wide range of applications. Its ease of maintenance combined with robust support services makes the CF1000 an intelligent investment for any business prioritizing efficiency, safety, and reliability in their heating systems.