SECTION VI - BURNER SPECIFICATIONS

NOTICE

V9A boiler ratings and capacities are based upon the following burners, pump pressures, nozzle sizes and manifold pressures. Refer to instructions furnished with burner for additional information regarding proper installation, fuel piping, wiring details, burner adjustments, service instructions and burner start-up.

Table V: Beckett Burner Specifications

OIL BURNERS

 

Burner

 

 

 

 

Burner Settings

 

Pump

 

Nozzle Data

Boiler

Burner

Burner

Air Tube

 

 

Pressure (PSI)

Nozzle

 

 

 

 

 

 

Model

Input

Mfr.

Model

Comb.

 

Air

Air

Air Damper

Low

High

Make

GPH x

(GPH)

Head

 

 

 

 

Shutter

Band

Low

High

Fire

Fire

 

Angle-Type

 

 

 

 

 

 

 

V903A

3.1

Beckett

CF-500

CF60KK

2

10

3

N/A

N/A

---

150

Hago

2.50 x 45° - P

V904A

4.2

Beckett

CF-800

CF80KH

1

8

0

N/A

N/A

---

150

Hago

3.40 x 45° - P

V905A

5.6

Beckett

CF-800

CF80KH

2

10

6

N/A

N/A

---

150

Hago

4.50 x 45° - P

V906A

7.0

Beckett

CF-1400

CF66KD

3

N/A

N/A

2.75

4.0

150

300

Hago

4.00 x 60° - P

V907A

8.3

Beckett

CF-1400

CF66KD

4

N/A

N/A

3.0

6.5

150

275

Hago

5.00 x 45° - P

V908A

9.6

Beckett

CF-1400

CF66KEE

1

N/A

N/A

3.5

8.5

150

300

Hago

5.50 x 45° - P

V909A

11.6

Beckett

CF-2300A

CF66KG

0

N/A

N/A

2.0

4.0

150

275

Hago

7.00 x 45° - P

V910A

13.2

Beckett

CF-2300A

CF66KG

1

N/A

N/A

2.0

6.0

150

275

Hago

8.00 x 45° - P

V911A

14.8

Beckett

CF-2500

CF66KP

0

N/A

N/A

0.5

3.0

275

275

Hago

(L) 4.50 x 45° - P

V912A

16.4

Beckett

CF-2500

CF66KP

0

N/A

N/A

0.5

4.0

275

275

Hago

(H) 5.00 x 45° - P

GAS BURNERS

Boiler

Burner

Burner

Burner

 

Damper

Settings

 

Manifold Pressure - “W.C.

Minimum Inlet Pressure

Input

Low

High

 

 

Low Fire

 

Model

Mfr.

Model

Shutter

Band

High Fire

- “W.C.

(MBH)

Fire

Fire

(Start)

 

 

 

 

 

 

 

V903A

447

Beckett

CG10.1S

---

---

10

1

(1.3)

2.5

3.24

V904A

606

Beckett

CG10.4S

---

---

5

2

(1.3)

2.6

3.64

V905A

808

Beckett

CG10.5S

---

---

7

1

(1)

3.3

4.61

V906A

1010

Beckett

CG10.6S

---

---

10

6

(1.1)

3.64

5.43

V907A

1198

Beckett

CG15.3S

18

43

---

---

0.9

3.1

5.31

V908A

1386

Beckett

CG15.4S

21

63

---

---

0.95

3.3

6.14

V909A

1674

Beckett

CG25.2S

23

47

---

---

0.8

3.43

4.69

V910A

1905

Beckett

CG25.3S

26

52

---

---

0.8

3.44

4.94

V911A

2136

Beckett

CG25.4S

28

58

---

---

0.8

3.0

4.88

V912A

2367

Beckett

CG50.2S

10

25

---

---

0.8

2.1

3.87

52

Image 52
Contents V9A Series Boiler Page Important Information Read Carefully USA BoilersPage Page Table of Contents Table of Contents Section I General Information Table I Boiler Ratings / Data Recommended Service Clearance Locate the UnitChimney or Vent Typical Arrangement for Stub Vent Right Section II Cast Iron Block Assembly Assembly of Sections Manual DRAW- UPSetting of Nipples V9A Section Arrangement Assembly of Sections Hydraulic DRAW-UP Front and Rear Section Channel Hydraulic Draw-Up Sections Section III Installation Instructions Bare Boiler Assembly Avoid Breathing Fiber Particulates and Dust Left Side Canopy Intermediate Bracket Mount Rear Observation Port Cover Refer to Figure Inspect ALL Boiler SealsV9A Series Jacket Assembly Boiler Models V903A thru V912A Burner Mounting Plate Refer to Figures 16 Mount Burner Adapter Plate to Burner Mounting PlateSteam Boilers Install Steam Trim Water Boilers Install Water TrimBurner Installation Packaged BoilerShipping Information Page V9A Series Minimum Piping Parallel Water Boiler V9A Series Minimum Piping Primary Secondary Water Boiler Page Page Page Page Page Page Page Mounting Elevations of M&M 150 Float Low Water Cut-Offs Schematic Tankless Heater Piping Page DHW Generation with Indirect Water Heater Water Boiler Pressure Relief Valve Hook-Up Always Inspect Installation Before Starting Burner Section IV Operating InstructionsBoiler and System Cleaning Steam Boiler Test ControlsBoiler and System Cleaning Water Boilers Frequent Water Addition Oxygen CorrosionSection V Service Instructions Clean the Boiler FluewaysMaintenance of LOW Water Cutoff Devices Probe Type LOW Water CutoffGeneral Maintenance Considerations Section VI Burner Specifications OIL BurnersCombination GAS / OIL Burners Table VII Webster Burner Specifications Section VII Repair Parts Head Band Low High FireSection VII Repair Parts Jacket Repair Parts Models V903A Thru V912A Bare Boiler Assembly Repair Parts for Bare Boiler Assembly Repair Parts for Bare Boiler Assembly Steam Trim / Water Trim Service Record Service Record

V9A specifications

Burnham V9A is a well-established model in the world of cast iron boilers, renowned for its efficiency and reliability in residential heating applications. As a part of Burnham's esteemed line of heating solutions, the V9A is designed to provide homeowners with consistent warmth while prioritizing fuel economy and ease of use.

One of the defining features of the Burnham V9A is its durable cast iron construction. This robust material enables the boiler to withstand high temperatures and pressures, ensuring a long service life. The V9A is engineered with several sections that are joined together, allowing for easier maintenance and potential adaptability to various heating demands. The boiler's design also promotes excellent heat retention, which not only enhances performance but contributes to overall energy efficiency.

In terms of technology, the Burnham V9A stands out with its advanced combustion design. With an efficiency rating of up to 85%, this model maximizes the heat output while minimizing fuel consumption. The boiler is compatible with both natural gas and propane, providing flexibility for users to choose their preferred fuel source. Additionally, the V9A is designed to operate with a minimum of venting requirements, making installation simpler and more cost-effective.

The Burnham V9A also features a choice of various firing rates, allowing homeowners to select the optimal heating output for their specific needs. This versatility ensures that the boiler can be effectively sized for different home environments, making it a highly adaptable option for a broad range of residential settings.

Moreover, one key characteristic of the Burnham V9A is its user-friendly control systems. It comes equipped with reliable electronic ignition and offers options for outdoor reset controls, which enhance efficiency by adjusting the boiler's operation based on the outdoor temperature. This advanced control capability not only optimizes energy use but also enhances comfort levels in the home.

Overall, the Burnham V9A represents a balance of durability, efficiency, and modern convenience, making it a top choice for homeowners seeking a reliable heating solution. Its combination of cast iron construction, advanced technology, and user-friendly features solidify its reputation in the competitive market of heating systems, ensuring comfort and peace of mind for years to come.