Brute Mini Hydronic Boiler | Page 23 |
|
|
Caution
Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.
Attention
En cas de surchauffe ou si l’admission de gaz ne peut être coupée, ne pas couper ni débrancher l’alimentation électrique de la pompe. Fermer plutôt le robinet d’admission de gaz à l’extérieur de l’appareil.
Caution
Do not attempt repairs on the gas controls or appliance. Tampering is dangerous and voids all warranties.
Attention
Ne tentez pas d’effectuer des réparations au système de régulation du débit du gaz ou à l’appareil. Toute modification non autorisée est dangereuse et entraîne l’annulation de toutes les garanties.
Caution
Keep all objects off the top of the boiler. Blocking air flow could damage the heater, and may void the warranty.
Attention
Ne posez aucun objet sur le dessus de l’appareil. Il pourrait empêcher la circulation de l’air, ce qui risquerait d’endommager, l’appareil et d’annuler la garantie.
7.3 Lighting and Shutdown Procedures
WARNING
Do not attempt to light the boiler with the burner cover off. Doing so may cause severe bodily injury.
AVERTISSEMENT
Ne tentez pas d’allumer l’appareil sans que la soit en place. Vous pourriez être victime de blessures corporelles graves.
Before starting your boiler, be sure that all of the functions and limits of the BJVS and BJVT boilers have been set according to the previous section of this manual (Section 7.2). Follow the instructions outlined below. Read and follow all safety instructions first. A more detailed set of lighting and shutdown instructions are listed on the label located on the boiler.
NOTE: If your boiler is configured to operate on LP gas and the LP tank runs out of fuel, turn off gas at the boiler. After the tank is refilled, the boiler must be relit following the instructions found on the boiler. DO NOT attempt repairs on the gas control or heater. Tampering is dangerous and voids all warranties.
WARNING
If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
AVERTISSEMENT
7.3.1 Lighting the Boiler
Lighting instructions are as follows:
1.Verify that the pump system is operating properly:
a.Shut off the manual gas valve located outside the boiler.
b.Raise the wall thermostat high enough to call for heat.
c.The pump should come on immediately. If it doesn't, test the electrical circuits.
2.Pilot Information:
a.The BJVS boilers do not require manual lighting. The pilot is controlled by the automatic ignition system.
b.The BJVT boilers do require manual pilot lighting. For access to the pilot burner, remove the louvered airbox cover by loosening the two thumb screws.
c.Different models of the BJV boiler utilize various gas valves. Although the gas valves may have different control knobs, they are all similar in operation. The BJVS gas valve has a