Bradford-White Corp Residential Gas-Fired Hydronic Boilers, BJVS, BJVT warranty Field Assembly

Page 5

Brute Mini Hydronic Boiler

Page 5

 

 

Dimensions in inches cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

Water

Gas

 

 

 

 

 

 

inches cm

 

 

 

 

 

 

Conn.

Conn.

Size*

A

 

B

 

C

 

D

 

E

 

 

V

in.

in.

50

13-3/8

34

27-3/4

71

23-5/8

60

21-3/4

55

26-1/2

67

4

10

1-1/4

1/2

75

13-3/8

34

27-3/4

71

24-1/8

61

21-3/4

55

27-1/2

70

5

13

1-1/4

1/2

100

16-7/8

43

28-3/4

73

24-1/8

61

22-3/4

58

27-1/2

70

5

13

1-1/4

1/2

125

16-7/8

43

28-3/4

73

23-5/8

60

22-3/4

58

27-1/2

70

6

15

1-1/4

1/2

160

20-3/8

52

28-3/4

73

23-5/8

60

22-3/4

58

27-1/2

70

6

15

1-1/4

1/2

225

25-5/8

65

31-1/2

80

23-1/4

59

23-3/4

63

27-1/2

70

7

18

1-1/4

*3/4**

* Values shown are for both BJVS and BJVT Models

 

 

 

 

 

 

 

**1/2 for propane

Figure 1. Dimensional Information.

2.2 Field Assembly

1.Brute Mini boilers have built-in draft diverter for natural draft operation.

2.Find the vent damper box which is located in the boiler package.

3.Install the vent damper directly to the top of the draft diverter outlet with the damper operator facing to the front of the boiler, and with the flow direction arrow pointing upward. Use the vent damper wire harness provided with the boiler to connect the vent damper to the boiler. The bracket end of the harness should be connected to the vent damper actuator.

4.For Model BJVS only: Install the metal plug provided with the vent damper onto the damper plate hole. Disregard the metal plug in case of standing (continuous) pilot boilers. For all

BJVT models, the damper plate hole should never be blocked.

5.Do not modify the automatic vent damper device. It is very important that no other vents are closed. Provide at least six inches clearance between the automatic vent damper and combustible construction, and be sure to allow access for servicing the damper.

6.Install the temperature/pressure gauge provided in the parts box.

Figure 2. Field Assembly Items.

Image 5
Contents Brute Mini Table of Contents General Information Specifications Installation InstructionsDiagnostic Tools General SpecificationsBjvt models, the damper plate hole should never be blocked Field AssemblyFlooring ClearancesExhaust Venting VentingCombustion Air Supply Venting Multiple Appliances Vent Pipe Sizing and General InstallationCommon Venting Systems Inspection of Commonly Vented Appliances Gas Supply and Piping Gas ConnectionsTypical design for a sediment trap/drip leg Special Precautions for LP GasWater Connections Adjusting the bypassWater Piping Alternate Auto-Bypass OperationTypical Plumbing Installations Multi-Zone Damage from improper flow is not warranted Flow RequirementsElectrical Main PowerChilled Water Systems Oxygen Permeable SystemsWiring Diagram, Spark Ignition System Bjvs 50 Wiring Diagram, Standing Pilot System Bjvt Wiring Diagram, Spark Ignition, Two-Stage Bjvs Multiple Zone Wiring Grounding Operating InstructionsAuxiliary Devices Normal OperationBoiler Start-up Start-upFilling the System Lighting the Boiler Lighting and Shutdown ProceduresComplete Shutdown High Altitude Burner Air Shutter AdjustmentShutdown Main Burner Shutdown Bjvt only General Maintenance MaintenanceBoiler Components and Their Operation General Boiler Troubleshooting TroubleshootingSymptom Cause Remedy Troubleshooting GuideStart Troubleshooting Honeywell S8600 Intermittent Pilot SystemGlossary of Terms Electrical TroubleshootingGlossary Ordering Information Replacement PartsParts List BJVS-50 BJVT-50 BJVS-75 BJVT-75 Jacket and Fire Box Components Parts Identification 11.3Exploded ViewBrute Mini Hydronic Boiler H2343000