Bradford-White Corp BJVT, BJVS warranty Replacement Parts, Ordering Information, Parts List

Page 31

Brute Mini Hydronic Boiler

Page 31

 

 

Heat Distribution Units

Transfers heat from the water supplied by the boiler to the area to be heated through the use of baseboard, convector, radiator, finned tube. Also known as "radiation."

Isolation Valve

Used to isolate the boiler from the circuit. It minimizes the amount of water drained from the system.

Primary-Secondary Piping

Two or more interconnecting circulating loops, each with its own pump.

Reverse-return Piping

Balanced, equal flow (first in, last out) piping. Utilized with multiple boilers and/or radiation. Applied with single system pumps, or primary-secondary pumps.

Side Wall Power Venter

This accessory allows the boiler exhaust to be routed horizontally through an adjoining outside wall, rather than gravity venting with a chimney or stack when local codes allow.

System Purge Valve

A device used to purge air from the circuit. Should be located as close as possible to the cold water feed, but not immediately after the cold water feed.

Trunk

The section of piping which connects the boiler return and supply with the branch(es). Also known as a "main" or "header." Should be same size as boiler inlet/outlet connections.

Vent Damper (optional in Canada)

Standard on BJV boilers. This energy-saving device prevents heated air from exiting the open vent when the boiler is not operating.

Zone Pump

Circulators installed in branch piping that divert hot water coming from the boiler into various areas (zones) of a building.

Zone Valve

Diverts hot water from the boiler into various areas (zones) of a building.

SECTION 11.

Replacement Parts

11.1 Ordering Information

To order or purchase parts for the Brute Mini BJVS or BJVT boiler, contact your nearest Representative. If you need assistance in finding a local dealer or distributor, contact the Technical Service Department.

NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. This information is on the rating plate on the heater.

11.2 Parts List

The following pages contain a parts list and a general exploded view to aid in parts identification. Please refer to these pages when ordering parts for your BJVS or BJVT boiler.

Image 31
Contents Brute Mini Table of Contents General Information General Specifications Installation InstructionsSpecifications Diagnostic ToolsBjvt models, the damper plate hole should never be blocked Field AssemblyFlooring ClearancesCombustion Air Supply VentingExhaust Venting Common Venting Systems Vent Pipe Sizing and General InstallationVenting Multiple Appliances Inspection of Commonly Vented Appliances Gas Supply and Piping Gas ConnectionsTypical design for a sediment trap/drip leg Special Precautions for LP GasAlternate Auto-Bypass Operation Adjusting the bypassWater Connections Water PipingTypical Plumbing Installations Multi-Zone Damage from improper flow is not warranted Flow RequirementsOxygen Permeable Systems Main PowerElectrical Chilled Water SystemsWiring Diagram, Spark Ignition System Bjvs 50 Wiring Diagram, Standing Pilot System Bjvt Wiring Diagram, Spark Ignition, Two-Stage Bjvs Multiple Zone Wiring Normal Operation Operating InstructionsGrounding Auxiliary DevicesFilling the System Start-upBoiler Start-up Lighting the Boiler Lighting and Shutdown ProceduresShutdown Main Burner Shutdown Bjvt only High Altitude Burner Air Shutter AdjustmentComplete Shutdown General Maintenance MaintenanceBoiler Components and Their Operation General Boiler Troubleshooting TroubleshootingSymptom Cause Remedy Troubleshooting GuideStart Troubleshooting Honeywell S8600 Intermittent Pilot SystemGlossary Electrical TroubleshootingGlossary of Terms Parts List Replacement PartsOrdering Information BJVS-50 BJVT-50 BJVS-75 BJVT-75 Jacket and Fire Box Components Parts Identification 11.3Exploded ViewBrute Mini Hydronic Boiler H2343000