Burnham SM-6 manual Repair Parts

Page 26

V. Repair Parts

All Spacemaster™ Repair Parts may be obtained through your local Burnham Wholesale distributor. Should you require assistance in locating a Burnham distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408.

Any parts not listed can be ordered by description or part number on the item.

 

 

 

 

Part No.

 

 

1.

Gas Valve - Honeywell VR8204C3007

81660145U

 

2.

Ignition Module - Honeywell S8670E1007*

80160108

 

3.

Differential Pressure Switch

60160880

 

4.

High Limit - Honeywell L4189B2012

80160460

4a.

Honeywell #45900409-003B Immersion Well (½"NPT)

80160461

 

5.

Circulator - TACO #005-T1

8056054

 

6.

Pilot - Honeywell Q362A1037

8236068

 

7.

Ignition/Sensor Cable Honeywell 394799-36

8236085

8a.

Main Gas Burner with Pilot Bracket and Orifice #AB24040 (3 section)

8236070

8b.

Main Gas Burner with Pilot Bracket and Orifice #AB24042 (4 section)

8236074

 

9.

Induced Draft Fan Replacement Assembly - Includes Fan (8116055),

6110303

 

Canopy Outlet Gasket, Fan Inlet Gasket and two (2) Fan Outlet Gaskets

 

 

 

 

 

10.

Fan Inlet Casting

8116056

11.

Temperature/Pressure Gauge

8056235

1

2a.

Lower Circulator Return Piping Assembly - 3 section

8060301

1

2b.

Lower Circulator Return Piping Assembly - 4 section

8060305

1

3a. Supply Piping Assembly - 3 section

8060302

1

3b. Supply Piping Assembly - 4 section

8060304

14.

Upper Circulator Return Piping Assembly

8060303

15.

Enclosure Gasket

8200301

16.

Canopy Outlet Gasket

8206034

17.

Fan Inlet Gasket

8206011

18.

Fan Outlet/Orifice Plate Gasket (2 required)

8200306

19.

Transformer/Relay Combination - Honeywell R8285D5001

80160156U

20.

Relay - Honeywell R8222U1006

80160096U

21.

Misc. Parts Carton 5" to 9" thick walls

6050301

22.

Misc. Parts Carton 9" to 15" thick walls

6050302

23.

Vent Tube - 2½" O.D. x 24" Lg.

8110301

24.

Vent Tube Mounting Flange

7110311

25a. Orifice Plate - 3 section

61103036

25b. Orifice Plate - 4 section

61103046

26.

Air Inlet Duct Gasket

8200307

27.

Flame Roll-Out Switch

80160044

*WARNING — The Honeywell S8670E Ignition Module incorporates a prepurge feature that is necessary for the safe operation of this boiler. Do not substitute any other Ignition Module.

26

Image 26
Contents Spacemastertm Important Information Please Read this page Carefully Table of Contents General Installation Requirements Boiler Location Must Meet the Following Site RequirementsMinimum Clearance to Combustible Surfaces ½ 1.6 ft ¾ 2.1 ft II. Installation Instructions Vent System Cross Section Oxygen Corrosion Recommended Boiler Piping Page Electric Wiring Installation Inspect Installation Before Starting Initial Start III. Operating InstructionsFollow These Operating Instructions Schematic Wiring Diagram Ladder Wiring Diagram Sequence of Operation Trouble Shooting Check GAS Input Rate to BoilerPage Page Page Typical Pilot Flame Main Burner Flame Removal of Burner Assembly IV. Service Burners and Firebox should be Cleaned Annually Maintenance of LOW Water CutoffLubrication Avoid Breathing Fiber Particulates and Dust Repair Parts VI. Low Water Cut Off Lwco WhenLimited Warranty