A. The Vent Damper is continuously powered at Terminal 1.

B.When there is a call for heat, the damper relay coil is energized through Terminal 5 if all limits ahead of the damper are satisfied.

C.The relay coil closes contacts which energize the damper motor, causing the damper to open.

D.When the damper blade reaches the fully open posi- tion, power is sent back to the ignition circuit through Terminal 2 and the damper motor is de-energized.

E.When the call for heat is satisfied, the damper relay coil

is deenergized - closing contacts which energize the damper motor. This causes the damper to close. When the damper blade reaches the fully closed position, the damper motor is de-energized.

POWER FAILURE - The damper blade will stop in the position it was in when power failed. (Combustion can never take place unless the damper blade is in the fully open position.)

Figure 9: Vent Damper Schematic Wiring Diagram

12

Image 12
Contents Price $3.00 PartNo.81417032R10-11/99Page 202 Clearances CanadaRemove Crate Determine type of space. Divide Volume by Total Input Boilerpiping Oxygen CorrosionLength Inch w.c. Pressure Drop Feet Installblockedventswitch Equivalent Length of FittingsRefer to in this manual Ifanexistingboilerisremoved Both of the aforementioned standards, AnsiSeal any unused openings in the common venting system Plug-in Damper Installation 54/ANSIZ223.1 VentdampersequenceofoperationEffikal and Johnson Damper Vent Damper Schematic Wiring Diagram Safety Shutdown Sequence of Operation Normal OperationPage Vent Damper will close see Paragraph 17E Page Pilot Sequence of Operation Normal Operation Wiring Schematic, Zone Valves Section II Operating Instructions Initial StartTop View of SV9500, SV9600 VR Gas Valves 21460147 For Your Safety Read Before Operating 81460177 Lighting InstructionsCheck GAS Input Rate to Boiler LP Gas InputCheck Pilot Burner Flame Check Ignition System Safety SHUT-OFF Device Move JumperCombustion Chamber BURN-OFF Typical Pilot Flame, Honeywell Q3450 Troubleshooting Guide, Honeywell Intermittent Ignition Section III Service Burner Cleaning and Installation Lubrication Manifold and Main BurnersPilot Burner and Gas Valve Burnham Corporation Regional Offices Contact Regional Office Indicated for your StateSection Assembly and Canopy Group Canopy Assembly Base Assembly Key Description Boiler QtyUSS Manifold and Main Burners Inch Main Burners Key Description Quantity Manifold and Main Burners 1 Inch Main Burners OnlyManifold and Main Burners Mm Main Burners Manifold and Main Burners 50 mm Main Burners Only 40MM Main Burners only Intermittent Ignition OnlyVolt Continuous Ignition Standing Pilot Natural Gas Only Volt Continuous Ignition Standing Pilot LP Gas OnlyNatural G as, Sea Level to 2000 Ft Burner Only 40mm Burner Only Burner Only 40mm Burner Only 40mm Burners Only Service Notes Key Quantity Description Key Description Quantity Water Trim Nipple, 1¼ NPT x 806600005 Transformer Continuous and Gravity Circulation Only Draft Hood Carton Vent Damper Carton U.S.A. Standard Canada OptionalVent Reducer

SERIES 2 specifications

The Burnham SERIES 2 is a highly regarded addition to the lineup of residential and commercial heating systems, known for its efficiency, reliability, and innovative design. Designed with the user in mind, the SERIES 2 boasts a range of main features that cater to the needs of modern heating solutions.

One of the standout characteristics of the Burnham SERIES 2 is its advanced cast iron construction. This material is renowned for its durability and excellent heat retention capabilities, ensuring that the system provides consistent warmth over extended periods. The cast iron heat exchanger allows for efficient heat transfer and maximizes energy output while minimizing heat loss.

Efficiency is a key focus for the Burnham SERIES 2, and it is designed to operate at high annual fuel utilization efficiency (AFUE) ratings. With its efficiency-enhancing features, including advanced combustion technology, the system helps homeowners save on energy costs while reducing their environmental footprint. The SERIES 2’s design helps ensure that a greater percentage of the fuel consumed is converted into usable heat, making it a smart choice for energy-conscious users.

Another significant feature is the versatile configuration options available with the Burnham SERIES 2. It can be installed in various settings, including basements, utility rooms, or even garages, due to its compact design. The system is compatible with multiple fuel types, allowing users to select between natural gas and propane to suit their specific preferences and availability.

The Burnham SERIES 2 also prioritizes ease of maintenance. Its user-friendly design includes access panels that simplify servicing and routine inspections. Additionally, it incorporates a range of safety features, such as an automatic shut-off system and built-in controls, to ensure safe operation.

In terms of technology, the SERIES 2 utilizes an innovative control system that optimizes heating cycles based on user demands and external conditions. This intelligent control enhances comfort and prevents excessive cycling, thereby prolonging the lifespan of the unit.

Overall, the Burnham SERIES 2 is distinguished by its robust construction, energy-efficient operation, versatility in installation, ease of maintenance, and advanced technology. For homeowners and businesses seeking a reliable heating solution, it represents a compelling choice, delivering warmth and comfort while remaining mindful of energy consumption and environmental impact.