Burnham SERIES 2 manual Base Assembly, Key Description Boiler Qty

Page 34

Figure 34: Base Assembly

Key

Description

Boiler

Part No.

Qty.

No.

Size

 

 

 

 

 

 

 

 

3. Base Assembly

 

 

 

 

 

 

 

 

 

 

202

618600291

1

 

 

 

 

 

 

 

202X

618600391

1

 

 

 

 

 

 

 

203

618600391

1

 

 

 

 

 

 

Base Assembly

204

618600491

1

 

 

 

 

 

(Complete)

205

618600591

1

 

 

3

Available for 1 Inch

 

 

 

206

618600691

1

 

Burners Only

 

 

 

 

 

 

 

207

618600791

1

 

 

 

 

 

 

 

208

618600891

1

 

 

 

 

 

 

 

209

618600991

1

 

 

 

 

 

 

 

210

618601091

1

 

 

 

 

 

 

 

202

718600291

1

 

 

 

 

 

 

 

202X

718600391

1

 

 

 

 

 

 

 

203

718600391

1

 

 

 

 

 

 

 

204

718600491

1

 

 

 

 

 

 

 

205

718600591

1

3A

Base Tray

 

 

 

206

718600691

1

 

 

 

 

 

 

 

 

 

207

718600791

1

 

 

 

 

 

 

 

208

718600891

1

 

 

 

 

 

 

 

209

718600991

1

 

 

 

 

 

 

 

210

718601091

1

 

 

 

 

 

Key

Description

Boiler

Part No.

Qty.

No.

Size

 

 

 

 

 

 

 

 

3. Base Assembly Continued

 

 

 

 

 

 

 

 

 

202

718600211

1

 

 

 

 

 

 

 

202X

718600311

1

 

 

 

 

 

 

 

203

718600311

1

 

 

 

 

 

 

 

204

718600411

1

 

 

 

 

 

 

 

205

718600511

1

3B

Base Wrapper

 

 

 

206

718600611

1

 

 

 

 

 

 

 

 

 

207

718600711

1

 

 

 

 

 

 

 

208

718600811

1

 

 

 

 

 

 

 

209

718600911

1

 

 

 

 

 

 

 

210

718601011

1

 

 

 

 

 

3B1

Base End Insulation

All

720601

2

 

 

 

 

 

 

 

202

72060025

1

 

 

 

 

 

 

 

202X

72060035

1

 

 

 

 

 

 

 

203

72060035

1

 

 

 

 

 

 

 

204

72060045

1

 

 

 

 

 

 

 

205

72060055

1

3B2

Base Rear Insulation

 

 

 

206

72060065

1

 

 

 

 

 

 

 

 

 

207

72060075

1

 

 

 

 

 

 

 

208

72060085

1

 

 

 

 

 

 

 

209

72060095

1

 

 

 

 

 

 

 

210

72060105

1

34

Image 34
Contents Price $3.00 PartNo.81417032R10-11/99Page 202 Canada ClearancesRemove Crate Determine type of space. Divide Volume by Total Input Oxygen Corrosion BoilerpipingLength Inch w.c. Pressure Drop Feet Installblockedventswitch Equivalent Length of FittingsRefer to in this manual Both of the aforementioned standards, Ansi IfanexistingboilerisremovedSeal any unused openings in the common venting system Plug-in Damper Installation Ventdampersequenceofoperation 54/ANSIZ223.1Effikal and Johnson Damper Vent Damper Schematic Wiring Diagram Safety Shutdown Sequence of Operation Normal OperationPage Vent Damper will close see Paragraph 17E Page Pilot Sequence of Operation Normal Operation Wiring Schematic, Zone Valves Section II Operating Instructions Initial StartTop View of SV9500, SV9600 VR Gas Valves 21460147 For Your Safety Read Before Operating 81460177 Lighting InstructionsLP Gas Input Check GAS Input Rate to BoilerCheck Pilot Burner Flame Move Jumper Check Ignition System Safety SHUT-OFF DeviceCombustion Chamber BURN-OFF Typical Pilot Flame, Honeywell Q3450 Troubleshooting Guide, Honeywell Intermittent Ignition Section III Service Burner Cleaning and Installation Manifold and Main Burners LubricationPilot Burner and Gas Valve Burnham Corporation Regional Offices Contact Regional Office Indicated for your StateSection Assembly and Canopy Group Canopy Assembly Base Assembly Key Description Boiler QtyUSS Manifold and Main Burners Inch Main Burners Key Description Quantity Manifold and Main Burners 1 Inch Main Burners OnlyManifold and Main Burners Mm Main Burners Manifold and Main Burners 50 mm Main Burners Only Volt Continuous Ignition Standing Pilot Natural Gas Only 40MM Main Burners onlyIntermittent Ignition Only Volt Continuous Ignition Standing Pilot LP Gas OnlyNatural G as, Sea Level to 2000 Ft Burner Only 40mm Burner Only Burner Only 40mm Burner Only 40mm Burners Only Service Notes Key Quantity Description Key Description Quantity Water Trim Nipple, 1¼ NPT x 806600005 Transformer Continuous and Gravity Circulation Only Vent Damper Carton U.S.A. Standard Canada Optional Draft Hood CartonVent Reducer

SERIES 2 specifications

The Burnham SERIES 2 is a highly regarded addition to the lineup of residential and commercial heating systems, known for its efficiency, reliability, and innovative design. Designed with the user in mind, the SERIES 2 boasts a range of main features that cater to the needs of modern heating solutions.

One of the standout characteristics of the Burnham SERIES 2 is its advanced cast iron construction. This material is renowned for its durability and excellent heat retention capabilities, ensuring that the system provides consistent warmth over extended periods. The cast iron heat exchanger allows for efficient heat transfer and maximizes energy output while minimizing heat loss.

Efficiency is a key focus for the Burnham SERIES 2, and it is designed to operate at high annual fuel utilization efficiency (AFUE) ratings. With its efficiency-enhancing features, including advanced combustion technology, the system helps homeowners save on energy costs while reducing their environmental footprint. The SERIES 2’s design helps ensure that a greater percentage of the fuel consumed is converted into usable heat, making it a smart choice for energy-conscious users.

Another significant feature is the versatile configuration options available with the Burnham SERIES 2. It can be installed in various settings, including basements, utility rooms, or even garages, due to its compact design. The system is compatible with multiple fuel types, allowing users to select between natural gas and propane to suit their specific preferences and availability.

The Burnham SERIES 2 also prioritizes ease of maintenance. Its user-friendly design includes access panels that simplify servicing and routine inspections. Additionally, it incorporates a range of safety features, such as an automatic shut-off system and built-in controls, to ensure safe operation.

In terms of technology, the SERIES 2 utilizes an innovative control system that optimizes heating cycles based on user demands and external conditions. This intelligent control enhances comfort and prevents excessive cycling, thereby prolonging the lifespan of the unit.

Overall, the Burnham SERIES 2 is distinguished by its robust construction, energy-efficient operation, versatility in installation, ease of maintenance, and advanced technology. For homeowners and businesses seeking a reliable heating solution, it represents a compelling choice, delivering warmth and comfort while remaining mindful of energy consumption and environmental impact.