Burnham SERIES 2 manual 202

Page 3

Figure 1

 

 

 

Dimensions [inches]

 

 

Gas

 

 

Approx.

Boiler

 

 

 

 

Connection

Water

Recommended

 

 

 

 

 

 

 

Shipping

Model

 

 

 

 

 

 

 

For

Content

Vent Size

Weight

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

Automatic

[gallons]

[1] [2]

A

B

C

D

E

F

G

(lb.)

 

Gas Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

202

18-3/4

10-3/4

6-3/8

4

45-5/8

8-1/2

10 [3]

1/2

2.5

3" dia. x 15 ft.

212

 

 

 

 

 

 

 

 

 

 

 

 

202X

20

12

6

4

45-5/8

8-1/2

4-3/4

1/2

3.2

4" dia. x 15 ft.

262

 

 

 

 

 

 

 

 

 

 

 

 

203

20

12

6

4

45-5/8

8-1/2

4-3/4

1/2

3.2

4" dia. x 15 ft.

262

 

 

 

 

 

 

 

 

 

 

 

 

204

23-1/4

15-1/4

7-5/8

5

47-1/8

9-1/8

4-3/4

1/2

4

5" dia. x 15 ft.

306

 

 

 

 

 

 

 

 

 

 

 

 

205

26-1/2

18-1/2

9-1/4

6

48-1/2

9-3/4

5-1/4

1/2

4.7

6" dia. x 15 ft.

354

 

 

 

 

 

 

 

 

 

 

 

 

206

29-3/4

21-3/4

10-7/8

6

48-1/2

9-3/4

5-1/4

1/2

5.5

6" dia. x 15 ft.

414

 

 

 

 

 

 

 

 

 

 

 

 

207

33

25

12-1/2

7

50-1/8

10-3/8

6-5/8

3/4

6.2

7" dia. x 15 ft.

458

 

 

 

 

 

 

 

 

 

 

 

 

208

36-1/4

28-1/4

14-1/8

7

50-1/8

10-3/8

6-5/8

3/4

7

7" dia. x 15 ft.

514

 

 

 

 

 

 

 

 

 

 

 

 

209

39-1/2

31-1/2

15-3/4

8

52

11

7-1/4

3/4

7.7

8" dia. x 15 ft.

550

 

 

 

 

 

 

 

 

 

 

 

 

210

42-3/4

34-3/4

17-3/8

8

52

11

7-1/4

3/4

8.5

8" dia. x 15 ft.

608

 

 

 

 

 

 

 

 

 

 

 

 

[1]15' chimney height is from bottom of draft hood opening to top of chimney.

[2]Refer to the National Fuel Gas Code, Apendix G for equivalent areas of circular and rectangular flue linings. Maximum Allowable Working Pressure - 30 PSI (Water Only)

[3]202 only. Dimension 'G' includes allowance for 4" x 3" reducer furnished with boiler. See Figure 8.

3

Image 3
Contents PartNo.81417032R10-11/99 Price $3.00Page 202 Clearances CanadaRemove Crate Determine type of space. Divide Volume by Total Input Boilerpiping Oxygen CorrosionLength Inch w.c. Pressure Drop Feet Equivalent Length of Fittings InstallblockedventswitchRefer to in this manual Ifanexistingboilerisremoved Both of the aforementioned standards, AnsiSeal any unused openings in the common venting system Plug-in Damper Installation 54/ANSIZ223.1 VentdampersequenceofoperationEffikal and Johnson Damper Vent Damper Schematic Wiring Diagram Sequence of Operation Normal Operation Safety ShutdownPage Vent Damper will close see Paragraph 17E Page Pilot Sequence of Operation Normal Operation Wiring Schematic, Zone Valves Initial Start Section II Operating InstructionsTop View of SV9500, SV9600 VR Gas Valves 21460147 For Your Safety Read Before Operating Lighting Instructions 81460177Check GAS Input Rate to Boiler LP Gas InputCheck Pilot Burner Flame Check Ignition System Safety SHUT-OFF Device Move JumperCombustion Chamber BURN-OFF Typical Pilot Flame, Honeywell Q3450 Troubleshooting Guide, Honeywell Intermittent Ignition Section III Service Burner Cleaning and Installation Lubrication Manifold and Main BurnersPilot Burner and Gas Valve Contact Regional Office Indicated for your State Burnham Corporation Regional OfficesSection Assembly and Canopy Group Canopy Assembly Key Description Boiler Qty Base AssemblyUSS Manifold and Main Burners Inch Main Burners Manifold and Main Burners 1 Inch Main Burners Only Key Description QuantityManifold and Main Burners Mm Main Burners Manifold and Main Burners 50 mm Main Burners Only Volt Continuous Ignition Standing Pilot LP Gas Only 40MM Main Burners onlyIntermittent Ignition Only Volt Continuous Ignition Standing Pilot Natural Gas OnlyNatural G as, Sea Level to 2000 Ft Burner Only 40mm Burner Only Burner Only 40mm Burner Only 40mm Burners Only Service Notes Key Quantity Description Key Description Quantity Water Trim Nipple, 1¼ NPT x 806600005 Transformer Continuous and Gravity Circulation Only Draft Hood Carton Vent Damper Carton U.S.A. Standard Canada OptionalVent Reducer

SERIES 2 specifications

The Burnham SERIES 2 is a highly regarded addition to the lineup of residential and commercial heating systems, known for its efficiency, reliability, and innovative design. Designed with the user in mind, the SERIES 2 boasts a range of main features that cater to the needs of modern heating solutions.

One of the standout characteristics of the Burnham SERIES 2 is its advanced cast iron construction. This material is renowned for its durability and excellent heat retention capabilities, ensuring that the system provides consistent warmth over extended periods. The cast iron heat exchanger allows for efficient heat transfer and maximizes energy output while minimizing heat loss.

Efficiency is a key focus for the Burnham SERIES 2, and it is designed to operate at high annual fuel utilization efficiency (AFUE) ratings. With its efficiency-enhancing features, including advanced combustion technology, the system helps homeowners save on energy costs while reducing their environmental footprint. The SERIES 2’s design helps ensure that a greater percentage of the fuel consumed is converted into usable heat, making it a smart choice for energy-conscious users.

Another significant feature is the versatile configuration options available with the Burnham SERIES 2. It can be installed in various settings, including basements, utility rooms, or even garages, due to its compact design. The system is compatible with multiple fuel types, allowing users to select between natural gas and propane to suit their specific preferences and availability.

The Burnham SERIES 2 also prioritizes ease of maintenance. Its user-friendly design includes access panels that simplify servicing and routine inspections. Additionally, it incorporates a range of safety features, such as an automatic shut-off system and built-in controls, to ensure safe operation.

In terms of technology, the SERIES 2 utilizes an innovative control system that optimizes heating cycles based on user demands and external conditions. This intelligent control enhances comfort and prevents excessive cycling, thereby prolonging the lifespan of the unit.

Overall, the Burnham SERIES 2 is distinguished by its robust construction, energy-efficient operation, versatility in installation, ease of maintenance, and advanced technology. For homeowners and businesses seeking a reliable heating solution, it represents a compelling choice, delivering warmth and comfort while remaining mindful of energy consumption and environmental impact.