Desa VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA installation manual

Page 11

INSTALLATION

Continued

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel.

10"

8"

6"

2 1/2"

Minimum Non-

Combustible(A)

Material

12"

Mantel Shelf

18"

 

20"

22"

 

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

24" 24" Models

Top of Fireplace

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

12"

10"

8"

6"

2 1/2"

Underside of Mantel Shelf

All minimum distances are

Minimum Non-

Combustible

Material

8"

Min.

12"

15"

18"

in inches

Log Set

20" 24" Models

Top of Fireplace Opening

Hood

Distances to

(GA6050, GA6052

Underside of

GA6053)

Mantel

 

Figure 7 - Minimum Mantel Clearances When Using Hood

112882-01D

www.desatech.com

11

Image 11
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Local Codes Product FeaturesRemote Control Accessories Product IdentificationUnusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Minimum Noncombustible Material Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationMasonry Screw Mounting Flanges Installing Heater Base AssemblyInstallation Items Needed Flexible Gas Hose If allowed by local codes FittingPropane/LP External Supply Tank Regulator Vent Pointing Down Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Minimum Cap Pipe Tee Gas Nipple Joint Sediment Trap ControlInstalling Optional Remote Accessories Wires Remote Control Volt Battery Unit Housing Volt Battery ClipPad Terminal Push Button Wires Clips White Wire From Receiver Control Valve Red Wire FromLog #4 Installing LogsLog #1 Log #3 Log #2 Left Grate Finger RightLog #5 Log #6 Log #3 Log #2 For Your Safety Read Before LightingOperating Heater Lighting InstructionsNatural Gas Manual Lighting ProcedureTo Turn OFF GAS To Appliance Propane/LP GasON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationThermostat Series Model GhrctbMain Burner Auto Shutoff FeatureInspecting Burners Pilot Flame PatternLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningTechnical Service Wiring DiagramReplacement Parts Service HintsEquipment Shutoff Valve GA5010 Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Ghrcb Series Information VideoIllustrated Parts Breakdown Parts List Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.