Desa VGL30PRA, VGL18NRA installation manual Gas leak. See Warning, Statement above

Page 27

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Heater produces a clicking/tick-

1.

Metal expanding while heating

1.

This is common with most heat-

ing noise just after burner is lit or

 

or contracting while cooling

 

ers. If noise is excessive, contact

shut off

 

 

 

qualified service person

 

 

 

 

 

 

Heater produces unwanted odors

1.

Heater burning vapors from

1.

Open window and ventilate

 

 

paint, hair spray, glues, clean-

 

room. Stop using odor causing

 

 

ers, chemicals, new carpet,

 

products while heater is running

 

 

etc. (See IMPORTANT state-

 

 

 

 

 

ment above)

 

 

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 15)

 

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 23)

 

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 15)

 

2.

Replace control valve

 

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 15)

112882-01D

www.desatech.com

27

Image 27
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Local Codes Product FeaturesRemote Control Accessories Product IdentificationUnusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Determining Minimum Mantel Clearances When Using a Hood Mantel ClearancesMinimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationMasonry Screw Mounting Flanges Installing Heater Base AssemblyInstallation Items Needed Flexible Gas Hose If allowed by local codes FittingPropane/LP External Supply Tank Regulator Vent Pointing Down Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Minimum Cap Pipe Tee Gas Nipple Joint Sediment Trap ControlInstalling Optional Remote Accessories Wires Remote Control Volt Battery Unit Housing Volt Battery ClipPad Terminal Push Button Wires Clips White Wire From Receiver Control Valve Red Wire FromLog #4 Installing LogsLog #1 Log #3 Log #2 Left Grate Finger RightLog #5 Log #6 Log #3 Log #2 For Your Safety Read Before LightingOperating Heater Lighting InstructionsNatural Gas Manual Lighting ProcedureTo Turn OFF GAS To Appliance Propane/LP GasON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationThermostat Series Model GhrctbMain Burner Auto Shutoff FeatureInspecting Burners Pilot Flame PatternCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningTechnical Service Wiring DiagramReplacement Parts Service HintsEquipment Shutoff Valve GA5010 Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Ghrcb Series Information VideoIllustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.