Desa VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA Moisture/condensation noticed

Page 26

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 5)

 

 

 

 

 

Heater produces a whistling noise

1.

Turning control knob to HI

1.

Turn control knob to LO

when burner is lit

 

position when burner is cold

 

position and let warm up for

 

 

 

 

a minute

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Have gas

 

 

 

 

line checked by local natural

 

 

 

 

or propane/LP gas company

 

3.

Air passageways on heater

3.

Observe minimum installa-

 

 

blocked

 

tion clearances (see pages 9

 

4.

Dirty or partially clogged

 

through 12)

 

4.

Clean burner (see Cleaning

 

 

burner orifice

 

and Maintenance, page 23) or

 

 

 

 

replace burner orifice

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

white powder residue

 

 

 

 

 

 

 

Remote does not function

1.

Battery is not installed.

1.

Replace 9-volt batteries in

 

 

Battery power is low

 

receiver and hand-held remote

 

 

 

 

control

26

www.desatech.com

112882-01D

Image 26
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Identification Product FeaturesRemote Control Accessories Local CodesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsCheck GAS Type Minimum Noncombustible Material Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Minimum Mantel Clearances Without Using Hood Installing Damper Clamp Accessory for Vented Operation Floor ClearancesFlexible Gas Hose If allowed by local codes Fitting Installing Heater Base AssemblyInstallation Items Needed Masonry Screw Mounting FlangesConnecting to GAS Supply Propane/LP External Supply Tank Regulator Vent Pointing DownMinimum Cap Pipe Tee Gas Nipple Joint Sediment Trap Control Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Remote Accessories White Wire From Receiver Control Valve Red Wire From Volt Battery ClipPad Terminal Push Button Wires Clips Wires Remote Control Volt Battery Unit HousingLog #3 Log #2 Left Grate Finger Right Installing LogsLog #1 Log #4Lighting Instructions For Your Safety Read Before LightingOperating Heater Log #5 Log #6 Log #3 Log #2Propane/LP Gas Manual Lighting ProcedureTo Turn OFF GAS To Appliance Natural GasGhrctb Optional HAND-HELD Remote OperationThermostat Series Model ON/OFF Series Model GhrcbPilot Flame Pattern Auto Shutoff FeatureInspecting Burners Main BurnerLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Moisture/condensation noticed Gas leak. See Warning Statement aboveService Hints Wiring DiagramReplacement Parts Technical ServiceInformation Video Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Ghrcb Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.