Desa VGL18NRA Inspecting Burners, Pilot Flame Pattern, Main Burner, Auto Shutoff Feature

Page 22

OPERATING HEATER

Continued

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 33 shows a correct pilot flame pattern. Figure 34 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 34

turn heater off (see To Turn Off Gas to Appli- ance, page 20)

see Troubleshooting, page 24

Note: The pilot flame on natural gas units will have a slight curve, but the flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Propane/LP Gas

Natural Gas

Figure 33 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Propane/LP Gas

Natural Gas

Figure 34 - Incorrect Pilot Flame Pattern

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

22

www.desatech.com

112882-01D

Image 22
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Identification Product FeaturesRemote Control Accessories Local CodesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsCheck GAS Type Mantel Clearances Determining Minimum Mantel Clearances When Using a HoodMinimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Installing Damper Clamp Accessory for Vented Operation Floor ClearancesFlexible Gas Hose If allowed by local codes Fitting Installing Heater Base AssemblyInstallation Items Needed Masonry Screw Mounting FlangesConnecting to GAS Supply Propane/LP External Supply Tank Regulator Vent Pointing DownMinimum Cap Pipe Tee Gas Nipple Joint Sediment Trap Control Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Remote Accessories White Wire From Receiver Control Valve Red Wire From Volt Battery ClipPad Terminal Push Button Wires Clips Wires Remote Control Volt Battery Unit HousingLog #3 Log #2 Left Grate Finger Right Installing LogsLog #1 Log #4Lighting Instructions For Your Safety Read Before LightingOperating Heater Log #5 Log #6 Log #3 Log #2Propane/LP Gas Manual Lighting ProcedureTo Turn OFF GAS To Appliance Natural GasGhrctb Optional HAND-HELD Remote OperationThermostat Series Model ON/OFF Series Model GhrcbPilot Flame Pattern Auto Shutoff FeatureInspecting Burners Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Moisture/condensation noticed Gas leak. See Warning Statement aboveService Hints Wiring DiagramReplacement Parts Technical ServiceInformation Video Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Ghrcb Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.