Desa VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA Volt Battery Clip

Page 17

INSTALLATION

Continued

8.Install remote receiver into receiver bracket using pads and push button clips provided with receiver (see Figure 20).

9.Connect wires to control valve at the TPTH and TH locations as shown in Figure 21. Note: Make sure excess wire does not interfere with burner or pilot.

10.If heater was removed from fireplace before installation of remote accessory, see Installing Heater Base Assembly on page 13 to reinstall heater into fireplace. Test gas connection for leaks (see Checking Gas Connections, pages 15 and 16).

11.If logs were removed from heater for install remote accessory, replace logs (see Installing Logs, pages 18 and 19).

9-Volt Battery

Battery

Clip

Bracket

Pad

Terminal

Push Button

 

 

Wires

Clips

 

 

 

Figure 20 - Installing Remote Receiver

White Wire

From Receiver

Control

Valve

Red Wire From

Receiver

Figure 21 - Connecting Wires

Installing Batteries for Remote Receiver and Hand Held Remote Control Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand- held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver behind receiver bracket mounted on base assembly.

2.Locate the battery clip mounted on the back of the receiver (see Figure 20).

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Installing 9-Volt Battery (Not Included) in Hand- Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

Terminal

Battery Cover

 

Wires

 

 

 

 

Remote

 

 

 

Control

9-Volt

 

Battery

Unit

 

 

Battery

 

 

 

Housing

 

 

 

 

Figure 22 - Installing Battery in Hand-

Held Remote Control Unit (CGHRCB

 

Series)

 

 

 

Remote

 

Terminal

Control Unit

 

 

 

9-Volt

Wires

 

 

 

 

 

Battery

 

 

 

 

 

 

Battery

Battery

 

 

Cover

 

 

 

Housing

 

 

 

Figure 23 - Installing Battery in Hand-

Held Remote Control Unit (CGHRCTB

 

Series)

 

112882-01D

www.desatech.com

17

Image 17
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Minimum Noncombustible Material Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyFlexible Gas Hose If allowed by local codes Fitting Masonry Screw Mounting FlangesPropane/LP External Supply Tank Regulator Vent Pointing Down Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsMinimum Cap Pipe Tee Gas Nipple Joint Sediment Trap Control Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Remote Accessories Pad Terminal Push Button Wires Clips Volt Battery ClipWhite Wire From Receiver Control Valve Red Wire From Wires Remote Control Volt Battery Unit HousingLog #1 Installing LogsLog #3 Log #2 Left Grate Finger Right Log #4Operating Heater For Your Safety Read Before LightingLighting Instructions Log #5 Log #6 Log #3 Log #2To Turn OFF GAS To Appliance Manual Lighting ProcedurePropane/LP Gas Natural GasThermostat Series Model Optional HAND-HELD Remote OperationGhrctb ON/OFF Series Model GhrcbInspecting Burners Auto Shutoff FeaturePilot Flame Pattern Main BurnerLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningReplacement Parts Wiring DiagramService Hints Technical ServiceReceiver and HAND-HELD Remote Control KIT Ghrcb Series Cleaning KIT CCKInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.