Desa VGL30PRA, VGL18NRA Floor Clearances, Installing Damper Clamp Accessory for Vented Operation

Page 12

INSTALLATION

Continued

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Combustible

14" Material

Min.

Noncombustible Material

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Hearth

Combustible Material

5"

Min.

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If you choose to use your heater as a manually- controlled model (no remote control installed), you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 29). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

 

Minimum

Chimney

Permanent Flue

Height (ft.)

Opening (sq. ins.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various

Standard

Round Flues

Diameter

Area

(inches)

(sq. inches)

520

629

739

851

Damper

ClampDamper

Damper

Masonry Fireplace

Manufactured

 

Fireplace

Figure 10 - Attaching Damper Clamp

12

www.desatech.com

112882-01D

Image 12
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Features Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsCheck GAS Type Determining Minimum Mantel Clearances When Using a Hood Mantel ClearancesMinimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Installing Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installation Items NeededFlexible Gas Hose If allowed by local codes Fitting Masonry Screw Mounting FlangesConnecting to GAS Supply Propane/LP External Supply Tank Regulator Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaMinimum Cap Pipe Tee Gas Nipple Joint Sediment Trap Control Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Remote Accessories Volt Battery Clip Pad Terminal Push Button Wires ClipsWhite Wire From Receiver Control Valve Red Wire From Wires Remote Control Volt Battery Unit HousingInstalling Logs Log #1Log #3 Log #2 Left Grate Finger Right Log #4For Your Safety Read Before Lighting Operating HeaterLighting Instructions Log #5 Log #6 Log #3 Log #2Manual Lighting Procedure To Turn OFF GAS To AppliancePropane/LP Gas Natural GasOptional HAND-HELD Remote Operation Thermostat Series ModelGhrctb ON/OFF Series Model GhrcbAuto Shutoff Feature Inspecting BurnersPilot Flame Pattern Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Moisture/condensation noticed Gas leak. See Warning Statement aboveWiring Diagram Replacement PartsService Hints Technical ServiceCleaning KIT CCK Receiver and HAND-HELD Remote Control KIT Ghrcb SeriesInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VGL18NRA, VGL30PRA, VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, VGL30PRA specifications

Desa VGL series offers a range of innovative and efficient lighting solutions, primarily catering to various lighting needs in residential and commercial spaces. The models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA have been designed to provide high-performance lighting while maintaining energy efficiency.

Each model in the Desa VGL lineup features a robust design, making them suitable for diverse environments. The VGL18NRA and VGL18PRA models are known for their compact size, making them ideal for smaller spaces while still delivering powerful illumination. These models utilize advanced LED technology, ensuring a longer lifespan and lower energy consumption compared to traditional lighting solutions.

In contrast, the VGL24NRA and VGL24PRA models offer a step up in brightness and area coverage, making them perfect for medium-sized settings. With enhanced lumen output and superior optical design, these lights can effectively illuminate larger areas, ensuring safety and visibility.

The VGL30NRA and VGL30PRA models harness cutting-edge features, providing maximum brightness and adaptability for larger commercial spaces. These models come equipped with smart technologies, including dimming options and motion sensors, allowing for customized lighting solutions based on specific needs. This makes them an excellent choice for dynamic environments where lighting requirements may change throughout the day.

All models in the Desa VGL series are designed with durability in mind, often featuring weather-resistant enclosures suitable for outdoor installations. Additionally, these lights are easy to install and maintain, making them a practical choice for both professional installations and DIY projects.

In summary, the Desa VGL series, encompassing models VGL18NRA, VGL18PRA, VGL24NRA, VGL24PRA, VGL30NRA, and VGL30PRA, stands out for its versatility, energy efficiency, and advanced technology. These lights not only serve diverse lighting needs across various environments but also promise longevity and reduced energy costs, making them an ideal choice for forward-thinking consumers and businesses alike.