Desa VGL18NRA, VGL30PRA Installing Heater Base Assembly, Installation Items Needed

Page 13

INSTALLATION

Continued

INSTALLING HEATER BASE ASSEMBLY

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplace floor with noncombus- tible material. Make sure material is secure.

tions included with the kit.

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper positions on heater base.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mount- ing flanges (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" masonry drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12).

11.Connect to gas supply. See Connecting To Gas

Supply, page 14.

Flexible Gas Hose

(if allowed by local codes)

Fitting

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base as- sembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane/LP gas, not pro- vided

electric drill with 3/16" masonry drill bit

Note: Install optional remote receiver and hand- held remote kit (see Accessories, page 29) before installing gas log heater. See installation instruc-

Figure 11 - Attaching Flexible Gas Hose

to Heater

Masonry

Screw

Mounting

Flanges

Figure 12 - Attaching Base Assembly to Fireplace Floor

112882-01D

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Mantel Clearances Determining Minimum Mantel Clearances When Using a Hood Minimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyFlexible Gas Hose If allowed by local codes Fitting Masonry Screw Mounting FlangesPropane/LP External Supply Tank Regulator Vent Pointing Down Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsMinimum Cap Pipe Tee Gas Nipple Joint Sediment Trap Control Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Optional Remote Accessories Pad Terminal Push Button Wires Clips Volt Battery ClipWhite Wire From Receiver Control Valve Red Wire From Wires Remote Control Volt Battery Unit HousingLog #1 Installing LogsLog #3 Log #2 Left Grate Finger Right Log #4Operating Heater For Your Safety Read Before LightingLighting Instructions Log #5 Log #6 Log #3 Log #2To Turn OFF GAS To Appliance Manual Lighting ProcedurePropane/LP Gas Natural GasThermostat Series Model Optional HAND-HELD Remote OperationGhrctb ON/OFF Series Model GhrcbInspecting Burners Auto Shutoff FeaturePilot Flame Pattern Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningReplacement Parts Wiring DiagramService Hints Technical ServiceReceiver and HAND-HELD Remote Control KIT Ghrcb Series Cleaning KIT CCKInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters