OPERATING

 

 

FOR YOUR SAFETY READ BEFORE LIGHTING

 

 

HEATER

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise

to the OFF position.

Ignitor Button

Control Knob

LOW

PILOT

 

OFF

HIGH

 

IGNITOR

 

Figure 15 - Control Knob In The OFF Position

Continued 17

100099

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety ContentsSafety Information Local Codes Product IdentificationUnpacking ProductCombustion Fresh AIR ForVentilation Producing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterRight Ceiling16 3/ 4 VGN30B FloorMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting Screws Connecting to GAS Supply Checking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsHeater OperatingPilot Operating HeaterBurner InspectingPilot Flame Pattern Shutting Off HeaterBurner Flame Pattern Inspecting BurnerCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionMaintenance CleaningTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting See CleaningFrom Top Ing statement atVGN30B Technical ServiceService Hints Parts Not Under Warranty Replacement PartsParts Under Warranty Floor Mounting Stand AccessoriesManual Shutoff ODS/Pilot KEY Part Number Description QTY VGN30B Parts List12-2 12-1 VN2000BB Limited Warranty Vanguard VENT-FREE Heaters Warranty Information