Desa VGN30B, VN2000BB Cleaning, Maintenance, Trouble Shooting, ODS/PILOT and Burner, Cabinet

Page 21

CLEANING

WARNING

AND

Turn off heater and let cool before cleaning.

MAINTENANCE

 

 

 

 

CAUTION

 

 

You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting and bedding material, sawdust, cobwebs, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

TROUBLE-

 

 

WARNING

 

 

 

 

 

SHOOTING

 

 

 

 

 

 

 

Turn off and unplug heater and let cool before servicing. Only a

 

 

Note: All troubleshooting

qualified service person should service and repair heater.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

items are listed in order of

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

Never use a wire, needle, or similar object to clean ODS/pilot. This

 

 

 

can damage ODS/pilot unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

 

 

When ignitor button

1.

Ignitor electrode posi-

1.

Replace ignitor

 

 

 

is pressed, there is no

 

tioned wrong

 

 

 

 

 

 

spark at ODS/pilot

2.

Ignitor electrode broken

2.

Replace ignitor

 

 

 

 

3.

Ignitor electrode not con-

3.

Reconnect ignitor cable

 

 

 

nected to ignitor cable

 

 

 

 

 

 

 

4.

Ignitor cable pinched or

4.

Free ignitor cable if

 

 

 

 

 

wet

 

pinched by any metal or

 

 

 

 

 

tubing. Keep ignitor

 

 

 

 

 

 

 

cable dry

 

 

 

 

5.

Piezo ignitor nut is loose

5.

Tighten nut holding

 

 

 

 

 

 

 

piezo ignitor to heater

 

 

 

 

 

 

 

cabinet. Nut is located

 

 

 

 

 

 

 

inside heater cabinet at

 

 

 

 

 

 

 

top

 

 

 

 

6.

Broken ignitor cable

6.

Replace ignitor cable

 

 

 

 

7.

Bad piezo ignitor

7.

Replace piezo ignitor

 

 

 

 

 

 

 

Continued

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100099

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety ContentsSafety Information Local Codes Product IdentificationUnpacking ProductCombustion Fresh AIR ForVentilation Producing Adequate VentilationFresh AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterRight Ceiling16 3/ 4 VGN30B FloorMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsHeater OperatingPilot Operating HeaterBurner InspectingPilot Flame Pattern Shutting Off HeaterBurner Flame Pattern Inspecting BurnerCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionMaintenance CleaningTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting See CleaningFrom Top Ing statement atTechnical Service Service HintsVGN30B Replacement Parts Parts Under WarrantyParts Not Under Warranty Accessories Manual ShutoffFloor Mounting Stand ODS/Pilot KEY Part Number Description QTY VGN30B Parts List12-2 12-1 VN2000BB Limited Warranty Vanguard VENT-FREE Heaters Warranty Information