FRESH AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2).

WARNING

WARNING ICON

G 001

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

12"

Figure 2 - Ventilation Air from Inside Building

Continued

100099

7

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety ContentsSafety Information Product Product IdentificationLocal Codes UnpackingProducing Adequate Ventilation Fresh AIR ForCombustion VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIRDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation AIRLocating Heater Installing To WallInstallation Items Check GAS TypeFloor CeilingRight 16 3/ 4 VGN30BMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Servicing. Correct all leaks at once Pressure Testing GAS Supply Piping SystemChecking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsHeater OperatingPilot Operating HeaterShutting Off Heater InspectingBurner Pilot Flame PatternIncorrect Flame Pattern AT High Position Inspecting BurnerBurner Flame Pattern Correct Flame Pattern AT High PositionODS/PILOT and Burner CleaningMaintenance Trouble ShootingTROUBLE- Shooting See CleaningFrom Top Ing statement atService Hints Technical ServiceVGN30B Parts Under Warranty Replacement PartsParts Not Under Warranty Manual Shutoff AccessoriesFloor Mounting Stand ODS/Pilot KEY Part Number Description QTY VGN30B Parts List12-2 12-1 VN2000BB Limited Warranty Vanguard VENT-FREE Heaters Warranty Information