Desa VN2000BB, VGN30B installation manual Ing statement at, Top

Page 24

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces a

1. Metal expanding while

1. This is common with

clicking/ticking noise

heating or contracting

most heaters. If noise is

just after burner is lit

while cooling

excessive, contact

or shut off

 

qualified service person

Heater produces

1.

Heater burning vapors

unwanted odors

 

from paint, solvents,

 

 

glues, etc. See IMPOR-

 

 

TANT statement above

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Checking Gas Connections, page 15)

Heater shuts off in

1.

Not enough fresh air is

use (ODS operates)

 

available

 

2.

Low line pressure

 

3.

ODS/pilot is partially

 

 

clogged

1.Open window and/or door for ventilation

2.Contact local natural gas company

3.Clean ODS/pilot (see Cleaning and Mainte- nance, page 17)

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position

 

top of page

 

Connections, page 15)

 

2.

Control valve defec-

2.

Replace control valve

 

 

tive

 

 

 

 

 

 

 

24

Gas odor during

1.

Foreign matter be-

combustion

 

tween control valve

 

 

and burner

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connections, page 15)

100099

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents SafetySafety Information Product Identification Local CodesUnpacking ProductFresh AIR For CombustionVentilation Producing Adequate VentilationFresh AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterCeiling Right16 3/ 4 VGN30B FloorInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingOperating HeaterOperating Heater PilotInspecting BurnerPilot Flame Pattern Shutting Off HeaterInspecting Burner Burner Flame PatternCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerSee Cleaning TROUBLE- ShootingFrom Ing statement at TopTechnical Service Service HintsVGN30B Replacement Parts Parts Under WarrantyParts Not Under Warranty Accessories Manual ShutoffFloor Mounting Stand ODS/Pilot VGN30B Parts List KEY Part Number Description QTY12-2 12-1 VN2000BB Warranty Information Limited Warranty Vanguard VENT-FREE Heaters