VFDM(18,24,30)LB LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch; Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service tech- nician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

GAS CONTROL KNOB SHOWN IN “OFF” POSITION

for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 2 through 6.

If knob does not pop up when released, stop and im- mediately callyou service technician or gas supplier

CONTROL KNOB INDICATOR

3.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas,

 

go to the next step.

 

THERMOCOUPLE

 

 

 

4.

Find pilot - the pilot is located in

(LPG)

 

front of the rear log.

 

PILOT

 

 

THERMOCOUPLE

5.

Turn manual gas control knob

(NAT)

 

 

counterclockwise

to

 

 

"PILOT."

 

 

6.Push in manual gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or use a match to light). Continue to hold the control knob in

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

7.Three heat settings can be selected by slightly depressing the manual gas control knob and turning the manual gas control

knob counterclockwise to 1, 2 or 3.

8.CAUTION! WHen the manual gas control knob has been turned to desired heat setting, ensure that the manual gas control knob is locked into that heat setting and cannot be turned without being depressed. If the manual gas control knob is in mid-position, between heat settings, incomplete combustion will take place, causing odor and may produce gas leakage or carbon monoxide.

TO TURN OFF GAS TO APPLIANCE

1.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

Page 20

23099-1-0707

Image 20
Contents Installation Instructions Table of Contents Important Safety Information Carbon Monoxide Poisoning MAY Lead to DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorWell Head Gas Installations Accessories for VFDR, VFDT, & VfdmAccessories for Vfdr only IntroductionProduct Specifications Model BTU/hr Max. Rate Med. Rate Min. RateGeneral Information Before you get startedMake sure you have received all parts High AltitudeClearances Glass DoorsInstalling as a Vented Appliance Sidewall & Ceiling Clearances FigureMantel Clearances Without Hood Figure Mantel Clearances with Hood FigureCombustible Material Fireplace PreparationInstalling Damper Clamp Figure Installing AS a Vented ApplianceBefore Fully Installing the Appliance Installing a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Recommended Gas Pipe DiameterVFDR,T,M18,24 & VFDR18LB10 LOG Placement 5 LOG SET Ember Material Placement on BurnerVFDR,T,M30 LOG Placement 7 LOG SET Ember Material Placement on BurnerOperation INSTRUCTIONS/FLAME Appearance Millivolt Valve for VFDR18LB10 SeriesMillivolt Valve for Vfdr Series Thermostat Valve for Vfdt SeriesWiring Vfdr Models only Check System OperationRemote Receiver Millivolt SystemVFDR18,24,30LB Lighting Instructions What to do if YOU Smell GASVFDR18LB10N,P Lighting Instructions VFDT18,24,30LB Lighting Instructions VFDM18,24,30LB Lighting Instructions Correct Pilot Flame Pattern for Vfdt & Vfdm Pilot Flame CharacteristicsIncorrect Pilot Flame Pattern for Vfdr Cleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningGas odor even when control knob is in OFF position Heater produces a whistling noise when main burner is litAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onHOW to Order Repair Parts Vfdr Series Parts ListVfdr Series Parts View VFDR18LB10 Parts List Index no DescriptionVFDR18LB 10 Parts View Vfdt Series Parts List Index Parts Numbers Description VFDT18LB VFDT24LB VFDT30LBVfdt Series Parts View Vfdm Series Parts List Index Part Numbers Description VFDM18LB VFDM24LB VFDM30LBVfdm Series Parts View Service Notes