PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR

This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air.

The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.Walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed, and

b.Weather-stripping has been added on openable windows and doors, and

c.Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between

wall-ceiling joints, between wall panels, at penetrations for plumb- ing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air.

Warning: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3. or applicable local codes.

Example of Large Room with 1/2 Wall divider.

Figure 1

The following formula can be used to determine the maximum heater rating per the definition of unconfined space:

Btu/Hr =

(L1

+ L2)FT x (W)FT x (H)FT

x 1000

 

 

50

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3.

Adhere to all codes, or in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from:

American National Standards Institute

11 West 42nd St.

New York, NY 10018

OR

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

CLEARANCES

Minimum Dimensions For Solid Fuel Burning Fireplaces UL127 Factory Built Fireplaces (Figure 2)

Model

A

B

C

D

VFDR18LB10

17"

12"

28"

17"

VFD(R,T,M)18

17"

12"

28"

17"

VFD(R,T,M)24

23"

12"

30"

18"

VFD(R,T,M)30

26"

12"

34"

20"

The dimensions shown and defined in the fireplace manufacturer’s instructions are minimum clearances to maintain in installing this heater. Left and right clearances are determined when facing the front of the heater.

Glass Doors

Make sure that glass doors are open during all operations of the logset. The opening of the glass door frame should be the dimension used for the minimum front opening of the firebox.

Figure 2

Follow these instructions to ensure safe installation.

Failure to follow instructions exactly can create a fire hazard.

Page 8

23099-1-0707

Image 8
Contents Installation Instructions Table of Contents Important Safety Information Carbon Monoxide Poisoning MAY Lead to DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorWell Head Gas Installations Accessories for VFDR, VFDT, & VfdmAccessories for Vfdr only IntroductionProduct Specifications Model BTU/hr Max. Rate Med. Rate Min. RateGeneral Information Before you get startedMake sure you have received all parts High AltitudeClearances Glass DoorsInstalling as a Vented Appliance Sidewall & Ceiling Clearances FigureMantel Clearances Without Hood Figure Mantel Clearances with Hood FigureCombustible Material Fireplace PreparationInstalling Damper Clamp Figure Installing AS a Vented ApplianceBefore Fully Installing the Appliance Installing a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Recommended Gas Pipe DiameterVFDR,T,M18,24 & VFDR18LB10 LOG Placement 5 LOG SET Ember Material Placement on BurnerVFDR,T,M30 LOG Placement 7 LOG SET Ember Material Placement on BurnerOperation INSTRUCTIONS/FLAME Appearance Millivolt Valve for VFDR18LB10 SeriesMillivolt Valve for Vfdr Series Thermostat Valve for Vfdt SeriesWiring Vfdr Models only Check System OperationRemote Receiver Millivolt SystemVFDR18,24,30LB Lighting Instructions What to do if YOU Smell GASVFDR18LB10N,P Lighting Instructions VFDT18,24,30LB Lighting Instructions VFDM18,24,30LB Lighting Instructions Correct Pilot Flame Pattern for Vfdt & Vfdm Pilot Flame CharacteristicsIncorrect Pilot Flame Pattern for Vfdr Cleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningGas odor even when control knob is in OFF position Heater produces a whistling noise when main burner is litAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onHOW to Order Repair Parts Vfdr Series Parts ListVfdr Series Parts View VFDR18LB10 Parts List Index no DescriptionVFDR18LB 10 Parts View Vfdt Series Parts List Index Parts Numbers Description VFDT18LB VFDT24LB VFDT30LBVfdt Series Parts View Vfdm Series Parts List Index Part Numbers Description VFDM18LB VFDM24LB VFDM30LBVfdm Series Parts View Service Notes