VFDT(18,24,30)LB LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electrical switch; Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service tech- nician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Set thermostat (gas control knob) to lowest setting.

3.Turn off all electric power to the appliance (if applicable).

4.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

CONTROL KNOB

INDICATOR

use a match to light). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 though 8.

If knob does not pop up when released, stop and im- mediately callyou service technician or gas supplier

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

GAS CONTROL KNOB

SHOWN IN “OFF”

POSITION

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

6.

Find pilot - the pilot is located in front

THERMOCOUPLE

 

of the rear log.

 

(LPG) PILOT

 

 

 

THERMOCOUPLE

7.

Turn manual gas control knob coun-

(NATURAL)

 

terclockwise

to "PILOT."

 

8.Push in manual gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or

9.Attention! Gas control has an INTERLOCK latching device. When the pilot is initially lit and the safety magnet is ener- gized (pilot stays "ON"), the INTERLOCK latching device becomes operative. If the gas control is turned to the "OFF" position or gas flow to the appliance is shut off, the pilot cannot be relighted until the safety magnet is de-energized (approximately 60 seconds). There will be an audible "click" when the safety magnet in the gas control is de-energized. Pilot can now be relighted. Repeat steps 4 through 8.

10.Turn gas control knob counterclockwise to "HIGH."

11.Turn on all electric power to the appliance (if applicable).

12.Set thermostat (gas control knob) to desired setting from "HIGH" to "LOW."

TO TURN OFF GAS TO APPLIANCE

1.Set thermostat (gas control knob) to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed (if applicable).

3.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

23099-1-0707

Page 19

Image 19
Contents Installation Instructions Table of Contents Carbon Monoxide Poisoning MAY Lead to Death Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Well Head Gas InstallationsAccessories for VFDR, VFDT, & Vfdm Accessories for Vfdr onlyModel BTU/hr Max. Rate Med. Rate Min. Rate Product SpecificationsHigh Altitude General InformationBefore you get started Make sure you have received all partsGlass Doors ClearancesMantel Clearances with Hood Figure Installing as a Vented ApplianceSidewall & Ceiling Clearances Figure Mantel Clearances Without Hood FigureFireplace Preparation Combustible MaterialBefore Fully Installing the Appliance Installing AS a Vented ApplianceInstalling Damper Clamp Figure Recommended Gas Pipe Diameter Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyEmber Material Placement on Burner VFDR,T,M18,24 & VFDR18LB10 LOG Placement 5 LOG SETEmber Material Placement on Burner VFDR,T,M30 LOG Placement 7 LOG SETThermostat Valve for Vfdt Series Operation INSTRUCTIONS/FLAME AppearanceMillivolt Valve for VFDR18LB10 Series Millivolt Valve for Vfdr SeriesMillivolt System Wiring Vfdr Models onlyCheck System Operation Remote ReceiverWhat to do if YOU Smell GAS VFDR18,24,30LB Lighting InstructionsVFDR18LB10N,P Lighting Instructions VFDT18,24,30LB Lighting Instructions VFDM18,24,30LB Lighting Instructions Incorrect Pilot Flame Pattern for Vfdr Pilot Flame CharacteristicsCorrect Pilot Flame Pattern for Vfdt & Vfdm Turn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingAppliance shuts off during use. Pilot stays on Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsVfdr Series Parts List HOW to Order Repair PartsVfdr Series Parts View Index no Description VFDR18LB10 Parts ListVFDR18LB 10 Parts View Index Parts Numbers Description VFDT18LB VFDT24LB VFDT30LB Vfdt Series Parts ListVfdt Series Parts View Index Part Numbers Description VFDM18LB VFDM24LB VFDM30LB Vfdm Series Parts ListVfdm Series Parts View Service Notes