BURNER INSTRUCTIONS
Check the following items during installation prior to | • Check all carryover ports for blockage from the ceramic |
lighting the multisided burner: | media |
• Check air shutter for correct setting. | o If there is blockage, use a small pointed tool to move |
the ceramic media away from the carryover port. | |
o NATgas |
|
for |
|
AIR SHUTTER 1/8” (3.2 mm) OPEN |
|
oLP gas - The air shutter setting must be Full Open for
AIR SHUTTER FULL OPEN
•For best results when lighting the burner, have the ad- justable flame knob to the HI position, then adjust to a lower setting after the burner has ignited.
| • When first lighting the pilot on the burner, it takes ap- |
| proximately 60 to 75 seconds to fully heat and energize |
NOTE: Orifice shield removed for photo clarity. | the thermopile. Once the thermopile is energized, turn |
on the gas valve and light the burner. |