Desa Tech CGR65PA, CGR65BPA, CGR35PA, CGR50BPA, CGR50PA Installing Radiants, Location of Radiants

Page 14

14

INSTALLING HEATER

Continued

INSTALLING RADIANTS

WARNING

WARNING ICON

G 001

Carefully handle the glass panel. Glass edges are rounded and buffed to prevent cuts, however, chipped or broken sections of glass can present sharp edges. These sharp edges can cut skin.

1.Remove glass guard from across opening at front of heater (see Figure 9).

2.Place radiants into combustion chamber through opening at front of heater. Front of radiant sits on front radiant support (see Figure 10). Back of radiant rests on back radiant support (see Figures 9 and 10).

Note: Radiants should never come in contact with burner flame. Contact with flame may cause carbon or soot deposits on radiants.

Burner

Glass

Guard

 

Combustion

 

Chamber

 

Back Radiant

 

Support

Lower

Lower Front

Access Area

 

Front Access

Panel

Glass Retaining

Channel

 

 

Figure 9 - Location of Radiants

 

Back Radiant Support

 

Radiant

Burner

Front Radiant Support

Figure 10 - Position of Radiant

100793

Image 14 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Product IdentificationInstallation Items FeaturesInstalling Heater UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see Figure Venting Heater Proper Size Vent Heater Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location AIR forVentilation Draft Hood Spillage TestCombustion Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateLighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner Orifice35,000 BTU/Hr 50,000 BTU/Hr Technical ServiceService Hints ModelOrdering Parts Under WarrantyParts Not Under Warranty PartsAccessories Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Warranty Information Limited Warranty Comfort Glow Vented Propane GAS Heaters