Desa Tech CGR50PA, CGR65BPA, CGR35PA, CGR50BPA, CGR65PA installation manual Venting Heater

Page 8

8

INSTALLING HEATER

Continued

VENTING HEATER

Note: Venting/chimney materials are not supplied with heater.

WARNING

WARNING ICON

G 001

A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes.

WARNING

WARNING ICON

G 001

This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting system is blocked. Do not operate heater if not properly vented. Do not tamper with the vent safety shut-off system. Carbon monoxide poisoning and death may result.

WARNING

WARNING ICON

G 001

When venting this heater, follow the safety information listed below.

Never vent heater to another room or inside a build- ing. Only vent heater to the outdoors.

Do not vent heater exhaust to a chimney or flue serving another solid-fuel-burning or gas appliance.

We recommend you use flues classified as prefabri- cated or masonry all-fuel chimney or type-B vent. See Vent Types, page 10.

If using old vent, check vent for soot, creosote, and loose particles. If vent is damaged, repair or replace it before using heater.

Extend the vertical section of vent pipe at least three feet above roof penetration.

Extend the vertical section of vent pipe at least two feet above the highest point of any roof within ten feet.

The horizontal run of vent pipe should rise at least 1/4 inch for each foot of run.

Support the vent pipe at least every five feet along its length. Do not use combustible materials to support vent pipe.

Never extend vent pipe horizontally through outside wall and terminate. You must connect a vertical run of vent pipe to the horizontal run. The vertical run must be at least 25% longer than the horizontal run.

Install vent or chimney cap that is approved for use with vented gas room heaters.

Do not use vent pipe smaller in diameter than that of the heater draft hood outlet.

Do not use dampers in the vent pipes.

Vertical height of vent must be greater than five feet above vent connection at draft hood.

100793

Image 8
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Product IdentificationFeatures Installing HeaterInstallation Items UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Heater Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation AIR for VentilationDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestCombustion Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateLighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Wiring DiagramBlower Changing Burner OrificeTechnical Service Service Hints35,000 BTU/Hr 50,000 BTU/Hr ModelParts Under Warranty Parts Not Under WarrantyOrdering PartsAccessories Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Warranty Information Limited Warranty Comfort Glow Vented Propane GAS Heaters

CGR50BPA, CGR65BPA, CGR65PA, CGR35PA, CGR50PA specifications

Desa Tech's CGR series, including the CGR50PA, CGR35PA, CGR65PA, CGR65BPA, and CGR50BPA, represents a cutting-edge line of gas logs designed for efficiency, reliability, and user-friendly operation. Each model combines modern engineering with top-tier technologies to deliver warmth and aesthetic appeal to any living space.

The CGR50PA is known for its compact yet powerful heating capabilities, offering a maximum input of 50,000 BTUs. This model is ideal for smaller rooms, providing consistent warmth without taking up excessive space. Its advanced burner technology ensures a realistic flame appearance, enhancing the ambiance of any setting.

The CGR35PA stands out with its lower BTU output of 35,000, making it perfect for cozy spaces or homes looking for a supplemental heating source. This model emphasizes energy efficiency, utilizing a state-of-the-art control system that optimizes fuel consumption while maintaining performance and comfort.

In contrast, the CGR65PA is designed for larger areas, boasting an impressive output of 65,000 BTUs. This model features a dual burner system, which not only increases heat distribution but also adds to the visual appeal with varying flame heights. Its robust construction guarantees durability, and an easy-to-use remote control provides added convenience.

The CGR65BPA variant further increases efficiency with its built-in blower system, which circulates warm air throughout the room, ensuring even heating. This model is particularly useful in expansive living areas where traditional heating methods may fall short. Its innovative safety features, including an oxygen depletion sensor, provide peace of mind for users.

Lastly, the CGR50BPA combines the advantages of its siblings, offering a balanced heating solution for medium-sized rooms. With a blower and adjustable thermostat, this model allows users to tailor their heating experience. Each unit in the CGR series is compatible with natural gas or propane, maximizing versatility based on individual preferences or regional availability.

Overall, the Desa Tech CGR series epitomizes modern gas log technology, focusing on performance, efficiency, and safety, making them an excellent choice for anyone seeking reliable and attractive heating solutions.