Desa Tech CGR65BPA, CGR35PA, CGR50BPA, CGR50PA Installing Glass Panel, For Radiant Models Only

Page 15

INSTALLING

INSTALLING GLASS PANEL

HEATER

For Radiant Models Only

1. Locate the glass panel package inside the back of the heater.

Continued

 

 

 

WARNING ICONG 001 CAUTION

 

 

Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for replacement glass panels.

WARNING ICONG 001 CAUTION

Do not operate heater without glass panels installed. Operating heater without glass panels will damage front of heater due to excess temperatures.

WARNING ICONG 001 CAUTION

Glass panels may have sharp edges. Handle with care.

2.Remove lower front access panel of heater by removing two screws at upper corners of panel. The lower front access panel covers the lower front access area (see Figure 9, page 14).

3.Remove two screws on glass guard. Remove glass guard (see Figure 11).

4.Carefully insert one glass panel up through lower front access area (see Figure 11).

5.Carefully slip glass panel behind hearth assembly (see Figure 11).

Glass

Guard

Screw

Hearth

Assembly

Glass

Panel

Lower Front

Access Area

Figure 11 - Inserting Glass Panels

Continued 15

100793

Image 15
Contents OWNER’S Operation and Installation Manual For Your SafetyWhat to do if YOU Smell GAS Contents Safety Information Safety Information Identification ProductUnpacking FeaturesInstalling Heater Installation ItemsLocating Heater Installing HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Heater Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test AIR forVentilation Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Combustion18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Viewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to ApplianceInspecting Pilot and Burner Flame Pilot Flame PatternBurner Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice WiringDiagram BlowerModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Parts Under WarrantyParts Not Under Warranty OrderingAccessories Blower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Limited Warranty Comfort Glow Vented Propane GAS Heaters Warranty Information

CGR50BPA, CGR65BPA, CGR65PA, CGR35PA, CGR50PA specifications

Desa Tech's CGR series, including the CGR50PA, CGR35PA, CGR65PA, CGR65BPA, and CGR50BPA, represents a cutting-edge line of gas logs designed for efficiency, reliability, and user-friendly operation. Each model combines modern engineering with top-tier technologies to deliver warmth and aesthetic appeal to any living space.

The CGR50PA is known for its compact yet powerful heating capabilities, offering a maximum input of 50,000 BTUs. This model is ideal for smaller rooms, providing consistent warmth without taking up excessive space. Its advanced burner technology ensures a realistic flame appearance, enhancing the ambiance of any setting.

The CGR35PA stands out with its lower BTU output of 35,000, making it perfect for cozy spaces or homes looking for a supplemental heating source. This model emphasizes energy efficiency, utilizing a state-of-the-art control system that optimizes fuel consumption while maintaining performance and comfort.

In contrast, the CGR65PA is designed for larger areas, boasting an impressive output of 65,000 BTUs. This model features a dual burner system, which not only increases heat distribution but also adds to the visual appeal with varying flame heights. Its robust construction guarantees durability, and an easy-to-use remote control provides added convenience.

The CGR65BPA variant further increases efficiency with its built-in blower system, which circulates warm air throughout the room, ensuring even heating. This model is particularly useful in expansive living areas where traditional heating methods may fall short. Its innovative safety features, including an oxygen depletion sensor, provide peace of mind for users.

Lastly, the CGR50BPA combines the advantages of its siblings, offering a balanced heating solution for medium-sized rooms. With a blower and adjustable thermostat, this model allows users to tailor their heating experience. Each unit in the CGR series is compatible with natural gas or propane, maximizing versatility based on individual preferences or regional availability.

Overall, the Desa Tech CGR series epitomizes modern gas log technology, focusing on performance, efficiency, and safety, making them an excellent choice for anyone seeking reliable and attractive heating solutions.