Desa Tech CGR35PA, CGR65BPA, CGR50BPA, CGR50PA, CGR65PA installation manual Ing statement at, Top

Page 31

TROUBLE-

WARNING ICONG 001 WARNING

SHOOTING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

REMEDY

 

 

 

PROBLEM

CAUSE

 

 

 

 

 

 

 

 

Heater produces

1. Heater burning vapors

1.

Ventilate room. Stop

unwanted odors.

 

from paint, hair spray,

 

using odor causing

 

 

glues, etc.

 

products while heater is

 

 

 

 

running.

 

2.

Low fuel supply

2.

Refill supply tank.

 

3.

Gas leak. See Warn-

3.

Find and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page.

 

Connections, page 13).

 

 

 

 

 

 

 

Heater shuts off in

1.

Heater not venting

1.

Check

venting system.

use.

 

correctly. Vent safety

 

If damaged or blocked,

 

 

switch shuts off

 

repair. If venting system

 

 

heater.

 

is OK,

have qualified

 

 

 

 

service

person replace

 

 

 

 

vent safety switch, wire

 

 

 

 

harness, or thermo-

 

 

 

 

couple interrupter.

 

2.

Low line pressure.

2.

Contact local propane

 

 

 

 

gas company.

 

3.

Pilot partially clogged.

3.

Clean pilot (see Clean-

 

 

 

 

ing and Maintenance,

 

 

 

 

page 26).

 

 

 

 

 

Gas odor even when

1. Gas leak. See Warn-

1.

Find and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position.

 

top of page.

 

Connections, page 13).

 

2.

Control valve damaged.

2.

Replace control valve.

 

 

 

 

 

Gas odor during

1. Foreign matter be-

1.

Take apart gas tubing

combustion.

 

tween control valve

 

and remove foreign

 

 

and burner.

 

matter.

 

 

 

 

2.

Gas leak. See Warn-

2.

Find and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page.

 

Connections, page 13).

 

3.

Foreign fumes in area

3.

Ventilate area around

 

 

of heater being drawn

 

heater to remove any

 

 

through burner com-

 

foreign fumes.

 

 

 

 

 

31

 

 

 

 

 

bustion.

 

 

 

 

 

 

 

 

 

 

 

100793

Image 31
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Safety Information Identification ProductUnpacking FeaturesInstalling Heater Installation ItemsLocating Heater Installing HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Heater Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test AIR forVentilation Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Combustion18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to AppliancePilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice WiringDiagram BlowerModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Parts Under WarrantyParts Not Under Warranty OrderingAccessories Blower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Limited Warranty Comfort Glow Vented Propane GAS Heaters Warranty Information

CGR50BPA, CGR65BPA, CGR65PA, CGR35PA, CGR50PA specifications

Desa Tech's CGR series, including the CGR50PA, CGR35PA, CGR65PA, CGR65BPA, and CGR50BPA, represents a cutting-edge line of gas logs designed for efficiency, reliability, and user-friendly operation. Each model combines modern engineering with top-tier technologies to deliver warmth and aesthetic appeal to any living space.

The CGR50PA is known for its compact yet powerful heating capabilities, offering a maximum input of 50,000 BTUs. This model is ideal for smaller rooms, providing consistent warmth without taking up excessive space. Its advanced burner technology ensures a realistic flame appearance, enhancing the ambiance of any setting.

The CGR35PA stands out with its lower BTU output of 35,000, making it perfect for cozy spaces or homes looking for a supplemental heating source. This model emphasizes energy efficiency, utilizing a state-of-the-art control system that optimizes fuel consumption while maintaining performance and comfort.

In contrast, the CGR65PA is designed for larger areas, boasting an impressive output of 65,000 BTUs. This model features a dual burner system, which not only increases heat distribution but also adds to the visual appeal with varying flame heights. Its robust construction guarantees durability, and an easy-to-use remote control provides added convenience.

The CGR65BPA variant further increases efficiency with its built-in blower system, which circulates warm air throughout the room, ensuring even heating. This model is particularly useful in expansive living areas where traditional heating methods may fall short. Its innovative safety features, including an oxygen depletion sensor, provide peace of mind for users.

Lastly, the CGR50BPA combines the advantages of its siblings, offering a balanced heating solution for medium-sized rooms. With a blower and adjustable thermostat, this model allows users to tailor their heating experience. Each unit in the CGR series is compatible with natural gas or propane, maximizing versatility based on individual preferences or regional availability.

Overall, the Desa Tech CGR series epitomizes modern gas log technology, focusing on performance, efficiency, and safety, making them an excellent choice for anyone seeking reliable and attractive heating solutions.