Desa Tech CGR50BPA, CGR65BPA, CGR35PA, CGR50PA, CGR65PA Installing Heater, Locating Heater

Page 7

INSTALLING HEATER

Continued

LOCATING HEATER

WARNING

WARNING ICON

G 001

Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances.

WARNING

WARNING ICON

G 001

Never install the heater

in a mobile home or a recreational vehicle.

where curtains, furniture, clothing, or other flam- mable objects are less than 48 inches from the front, 53 inches from the top, 12 inches from the right side and 6 inches from the left side and back of heater.

directly on carpeting, tile, or other combustible materials other than wood flooring. Place heater on metal or wood panel extending the full width and depth of heater.

as a fireplace insert.

in high traffic areas.

in windy or drafty areas.

CAUTION

WARNING ICON

G 001

If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it.

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service.

in coldest part of room.

near an electrical outlet if heater has blower or if you are planning to add blower to heater. See Accessories, page 37 for blower.

 

CEILING

6"

 

Minimum

53"

 

Minimum

Left

Right

Side

Side

 

6" Minimum

from Back

12"

Minimum

48" Minimum from Front of Heater

Figure 3 - Heater Clearances

Continued

100793

7

Image 7
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Safety Information Identification ProductUnpacking FeaturesInstalling Heater Installation ItemsLocating Heater Installing HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Heater Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Draft Hood Spillage Test AIR forVentilation Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Combustion18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Shutting Off Heater Manual Lighting ProcedureBlower Operation To Turn OFF GAS to AppliancePilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Changing Burner Orifice WiringDiagram BlowerModel Technical ServiceService Hints 35,000 BTU/Hr 50,000 BTU/HrParts Parts Under WarrantyParts Not Under Warranty OrderingAccessories Blower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Limited Warranty Comfort Glow Vented Propane GAS Heaters Warranty Information

CGR50BPA, CGR65BPA, CGR65PA, CGR35PA, CGR50PA specifications

Desa Tech's CGR series, including the CGR50PA, CGR35PA, CGR65PA, CGR65BPA, and CGR50BPA, represents a cutting-edge line of gas logs designed for efficiency, reliability, and user-friendly operation. Each model combines modern engineering with top-tier technologies to deliver warmth and aesthetic appeal to any living space.

The CGR50PA is known for its compact yet powerful heating capabilities, offering a maximum input of 50,000 BTUs. This model is ideal for smaller rooms, providing consistent warmth without taking up excessive space. Its advanced burner technology ensures a realistic flame appearance, enhancing the ambiance of any setting.

The CGR35PA stands out with its lower BTU output of 35,000, making it perfect for cozy spaces or homes looking for a supplemental heating source. This model emphasizes energy efficiency, utilizing a state-of-the-art control system that optimizes fuel consumption while maintaining performance and comfort.

In contrast, the CGR65PA is designed for larger areas, boasting an impressive output of 65,000 BTUs. This model features a dual burner system, which not only increases heat distribution but also adds to the visual appeal with varying flame heights. Its robust construction guarantees durability, and an easy-to-use remote control provides added convenience.

The CGR65BPA variant further increases efficiency with its built-in blower system, which circulates warm air throughout the room, ensuring even heating. This model is particularly useful in expansive living areas where traditional heating methods may fall short. Its innovative safety features, including an oxygen depletion sensor, provide peace of mind for users.

Lastly, the CGR50BPA combines the advantages of its siblings, offering a balanced heating solution for medium-sized rooms. With a blower and adjustable thermostat, this model allows users to tailor their heating experience. Each unit in the CGR series is compatible with natural gas or propane, maximizing versatility based on individual preferences or regional availability.

Overall, the Desa Tech CGR series epitomizes modern gas log technology, focusing on performance, efficiency, and safety, making them an excellent choice for anyone seeking reliable and attractive heating solutions.