Desa Tech CGR50PA, CGR65BPA, CGR35PA, CGR50BPA, CGR65PA Illustrated Parts List, Blower Assembly

Page 38

ILLUSTRATED

PARTS LIST

Blower

Assembly

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.

1

2

9

3

4

8

5 6

7

 

 

 

PART NUMBER FOR

 

 

 

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

CGR65BPA

CGR65PA

 

CGR50BPA

CGR50PA

CGR35PA

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

 

1

099998-01

——

 

099998-01

——

——

Fan Switch

1

2

100045-01

——

 

100045-01

——

——

Wire Harness

1

3

231942

——

 

231942

——

——

Fan Limit Switch

1

4

M11084-38

——

 

M11084-38

——

——

Screw, #8-18 x 3/8"

2

5

100121-01

——

 

100121-01

——

——

Blower

1

6

M11084-26

——

 

M11084-26

——

——

Screw, #10-16 x 3/8"

6

7

531001

——

 

531001

——

——

Blower Pan

1

8

098304-01

——

 

098304-01

——

——

Screw, #10-24 x 3/8"

1

9

099123-01

——

 

099123-01

——

——

Thermobulb Clip

1

 

 

 

 

 

 

 

 

 

38

100793

Image 38 Contents
What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Product IdentificationInstallation Items FeaturesInstalling Heater UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Heater Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location AIR forVentilation Draft Hood Spillage TestCombustion Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateLighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Blower Wiring Diagram Changing Burner Orifice35,000 BTU/Hr 50,000 BTU/Hr Technical ServiceService Hints ModelOrdering Parts Under WarrantyParts Not Under Warranty PartsAccessories Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Warranty Information Limited Warranty Comfort Glow Vented Propane GAS Heaters