Desa Tech CGR65PA, CGR65BPA, CGR35PA, CGR50BPA, CGR50PA installation manual Safety Information

Page 4

SAFETY INFORMATION

Continued

WARNINGS Continued

WARNING ICON

G 001

7.Provide the following minimum heater clearances from combustibles (as viewed from the front of heater):

Front: 48 inches

Back: 6 inches

Top: 53 inches

Right Side: 12 inches

Left Side: 6 inches

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Never place clothing or any flammable objects on the heater or venting system.

10.Heater and venting system surfaces are very hot during operation. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Carefully supervise young children when they are in the same room as heater. Heater will remain hot for a time after shutdown. Let surface cool before touching.

11.Do not use heater as a cooking device.

12.Do not alter heater or its controls. Any change may create a safety hazard.

13.Turn off heater and unplug (if equipped with blower) and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

14.Replace any safety screen or guard removed for servicing before running heater.

15.Do not use heater if any part has been under water. Immediately call a qualified service person to inspect the heater and to replace any part of the control system and any gas control which has been underwater.

4

100793

Image 4 Contents
For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety Information Safety Information Product IdentificationFeatures Installing HeaterInstallation Items UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Heater Gas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Radiants Location of RadiantsInstalling Glass Panel For Radiant Models OnlyInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation AIR for VentilationDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestCombustion Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 18 to make sure fresh air ventilation is adequateOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Flame Cleaning MaintenanceTrouble Shooting Observed Possible Problem Cause RemedyCleaning and Mainte TROUBLE- ShootingSee Changing Burner Orifice, Lighting Instructions Ing statement at TopService Procedures Removing Control Valve and Burner TubeRemoving Burner Wiring DiagramBlower Changing Burner OrificeTechnical Service Service Hints35,000 BTU/Hr 50,000 BTU/Hr ModelParts Under Warranty Parts Not Under WarrantyOrdering PartsAccessories Illustrated Parts List Blower AssemblyIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100793 100793 Warranty Information Limited Warranty Comfort Glow Vented Propane GAS Heaters