Enerco HSBF10NG, TSIR20NGT, TSBF10NG, MHBF6NG Thermostat models, BF20NGT BF30NGT, IR30NGT

Page 17

Thermostat models

3

26

14

24

1-4

1-1

34

43

 

9

42 6

29

5

15

22-1

11

8

45

7

 

 

4

 

 

 

 

 

16-1

 

33-1

 

 

16-2

 

 

 

1-3

1-2

BF20NGT

BF30NGT

3

16

2

27-2

 

 

28-2

22-3

 

25

22-2

 

 

 

24

1-4

34

1-1

 

 

 

42

 

 

9

6

 

 

 

 

 

22-1

 

 

26

11

8

 

 

1-3

44 13

23

29

5

7

IR20NGT

IR30NGT 38

39

16-1

16-2

 

33-1

 

 

45

 

 

 

 

 

 

 

35

 

 

22-3

 

 

 

 

 

 

 

 

 

 

 

19

 

 

4

 

 

23

 

 

 

18

13

 

 

 

 

 

 

27-1

2

 

44

 

 

 

 

 

 

28-1

22-2

25

 

 

 

 

 

16

21

36

 

 

 

 

 

 

 

 

10

1-2

Unvented Natural Gas Fired Room Heater 17

Installation Instructions and Owner’s Manual

Image 17
Contents MHBF30NGT MHBF20NGT MHBF6NG HSBF30NGT HSBF20NGT Blue Flame Heaters­ Plaque Heaters­TSBF30NGT TSBF20NGT HSBF10NG TSBF10NG MHIR30NGT MHIR20NGT HSIR30NGT HSIR20NGT HSIR10NG TSIR30NGT TSIR20NGT TSIR10NGNatural Gas PrecautionsCarbon Monoxide Poisoning Thermostatic Control on Thermostat Models Safety DeviceLocal Codes Ignition SystemVentilation from Inside Building Determining the Type of Heater Location SpaceVentilation AIR This Installation Requires Installation Check GAS TypeVentilation from Outdoors Locating HeaterMounting Bracket Fastening Heater to WallInstalling Support Feet see figure Installing Bottom Mounting ScrewsConnecting to GAS Supply Placing Heater on Mounting BracketTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaElectrical Wiring Diagram Pressure Testing Heater Gas ConnectionsFor Your Safety Read Before Lighting Operating Your HeaterFor IR only Lighting InstructionsOperating Your Heater Thermostat Models To Turn OFF GAS to ApplianceShutting OFF Heater Shutting OFF Burner only Pilot Stays LITInspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame PatternCleaning ODS/PILOT and Burner Cleaning and MaintenanceCleaning Burner Pilot AIR Hole Inlet Cleaning Heater CabinetObserved SYMPTOM­ Possible CAUSE­ REMEDY­ TroubleshootingObserved SYMPTOM­ Possible CAUSE­ REMEDY­ Troubleshooting CON’TBF6NG BF10NG­ BF20NGT BF30NGT­ SpecificationsIR10NG­ IR20NGT­ IR30NGT­ BF20NGT BF30NGT Thermostat modelsIR20NGT IR30NGTIR20NGT­ BF20NGT­ IR30NGT­ BF30NGT­ For all models, Equipment shutoff valve with 1/8 NPT tapITEM­ Part NO.­ Not sold separately Must purchase Assembly * Items not shown IR10NG­ BF6NG BF10NG­ IR10NG, BF6NG and BF10NG Parts ListITEM­ Part NO.­ DESCRIPTION­ BF6NG3 BF10NG NON-Thermostat modelsIR10NG Parts Under Warranty REPLACEMENT­PARTSParts not Under Warranty Technical ServiceUnvented Natural Gas Fired Room Heater Model ­ Serial No. ­ Date Purchased ­ Warranty Information
Related manuals
Manual 24 pages 60.4 Kb

MHBF10NG, HSIR20NGT, HSBF10NG, MHIR10NG, MHIR20NGT specifications

The Enerco HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG are a line of innovative heating solutions designed to meet various heating needs in both residential and commercial applications. Each model is engineered with advanced technologies and features that prioritize efficiency, performance, and user convenience.

The HSIR10NG is a high-efficiency infrared heater that operates on natural gas. It provides powerful heating with minimal energy consumption, utilizing infrared technology to warm objects and people directly rather than just the surrounding air. This results in faster heating and lower energy costs, making it an ideal choice for garages, workshops, or outdoor spaces.

Following closely is the TSIR10NG, another natural gas infrared heater known for its compact design and efficiency. This model features a state-of-the-art burner design that maximizes heat output while ensuring low emissions. The TSIR10NG is particularly suited for smaller spaces, providing targeted heating where it is needed most. It can easily be mounted on walls or ceilings, offering versatility in installation options.

The TSBF10NG is a dual-fuel infrared heater, allowing users to switch between natural gas and propane as needed. This flexibility makes it suitable for various environments and user preferences. The heater's robust construction ensures durability, while its adjustable heating levels allow for customized comfort.

For larger areas, the TSIR20NGT offers an enhanced heating capacity with similar infrared technology. This model is ideal for industrial or commercial spaces requiring efficient heating. With its advanced thermostat controls, users can maintain a consistent temperature while benefiting from lower operational costs.

Lastly, the MHBF6NG is a portable heating solution designed for versatility and convenience. This compact model is perfect for temporary heating needs, featuring an easy-to-use design that allows for quick setup and relocation. Its propane compatibility makes it a popular choice for outdoor events, workshops, or emergency heating situations.

Each model is equipped with advanced safety features, including automatic shutoff mechanisms and durable heat-resistant materials, ensuring peace of mind during operation. The Enerco line is engineered not only for performance but also for ease of maintenance, making them reliable options for users seeking efficient heating solutions. Overall, Enerco's HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG provide a range of effective heating options tailored to diverse environments and user needs, combining innovation with practical functionality.