1.Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep.

2.Fold wall anchor as shown in figure 8 below.

Figure 8.

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2” or less) insert red key into wall anchor.

5.Place mounting bracket onto wall. Line up holes on each end of bracket with wall anchors.

6.Insert mounting screws through bracket and into wall anchors.

7.Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater on Mounting Bracket

1.Locate two horizontal slots on back pane of heater (see figure 9).

2.Place heater onto mounting bracket. Slide hori- zontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Mounting Bracket mounted to wall

Figure 9.

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see figure 10).

Figure 10

2.Mark screws locations on wall.

3.Remove heater from mounting bracket.

4.If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching to Wall using Anchor. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64” drill bit.

5.Re-place heater onto mounting bracket.

6.Place spacers between bottom mounting holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With the other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly se- cured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. Re- place front panel after making gas connections and checking for leaks.

FLOOR MOUNTING AWAY FROM WALL:

Figure 11

Installing Support Feet (see figure 11)

1.Lay heater onto table on its back with bottom edge overhanging table edge.

2.Securely attach feet to bottom of heater using 2 – self-tapping screws each.

Note: Feet should have long end going out the front of heater, and the edge coinciding with side of heater. If feet overhang side of the heater, switch leg location.

3.Place heater on non-combustible surface (see Locating Heater above) before proceeding with gas connection. If this will be a permanent loca- tion, heater may be locked into position using anchoring holes in mounting feet.

Note: Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.­

Unvented Natural Gas Fired Room Heater

7

Installation Instructions and Owner’s Manual

Image 7
Contents HSIR30NGT HSIR20NGT HSIR10NG TSIR30NGT TSIR20NGT TSIR10NG Blue Flame Heaters­ Plaque Heaters­MHBF30NGT MHBF20NGT MHBF6NG HSBF30NGT HSBF20NGT TSBF30NGT TSBF20NGT HSBF10NG TSBF10NG MHIR30NGT MHIR20NGTCarbon Monoxide Poisoning PrecautionsNatural Gas Ignition System Safety DeviceThermostatic Control on Thermostat Models Local CodesVentilation AIR Determining the Type of Heater Location SpaceVentilation from Inside Building Locating Heater Installation Check GAS TypeThis Installation Requires Ventilation from OutdoorsMounting Bracket Fastening Heater to WallPlacing Heater on Mounting Bracket Installing Bottom Mounting ScrewsInstalling Support Feet see figure Connecting to GAS SupplyTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaOperating Your Heater Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram For Your Safety Read Before LightingFor IR only Lighting InstructionsShutting OFF Burner only Pilot Stays LIT To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF HeaterBurner Flame Pattern Thermostat Control OperationInspecting Burner Pilot Flame PatternCleaning Heater Cabinet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Hole InletObserved SYMPTOM­ Possible CAUSE­ REMEDY­ TroubleshootingObserved SYMPTOM­ Possible CAUSE­ REMEDY­ Troubleshooting CON’TIR10NG­ IR20NGT­ IR30NGT­ SpecificationsBF6NG BF10NG­ BF20NGT BF30NGT­ IR30NGT Thermostat modelsBF20NGT BF30NGT IR20NGTITEM­ Part NO.­ For all models, Equipment shutoff valve with 1/8 NPT tapIR20NGT­ BF20NGT­ IR30NGT­ BF30NGT­ Not sold separately Must purchase Assembly * Items not shown ITEM­ Part NO.­ DESCRIPTION­ IR10NG, BF6NG and BF10NG Parts ListIR10NG­ BF6NG BF10NG­ IR10NG NON-Thermostat modelsBF6NG3 BF10NG Technical Service REPLACEMENT­PARTSParts Under Warranty Parts not Under WarrantyUnvented Natural Gas Fired Room Heater Model ­ Serial No. ­ Date Purchased ­ Warranty Information
Related manuals
Manual 24 pages 60.4 Kb

MHBF10NG, HSIR20NGT, HSBF10NG, MHIR10NG, MHIR20NGT specifications

The Enerco HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG are a line of innovative heating solutions designed to meet various heating needs in both residential and commercial applications. Each model is engineered with advanced technologies and features that prioritize efficiency, performance, and user convenience.

The HSIR10NG is a high-efficiency infrared heater that operates on natural gas. It provides powerful heating with minimal energy consumption, utilizing infrared technology to warm objects and people directly rather than just the surrounding air. This results in faster heating and lower energy costs, making it an ideal choice for garages, workshops, or outdoor spaces.

Following closely is the TSIR10NG, another natural gas infrared heater known for its compact design and efficiency. This model features a state-of-the-art burner design that maximizes heat output while ensuring low emissions. The TSIR10NG is particularly suited for smaller spaces, providing targeted heating where it is needed most. It can easily be mounted on walls or ceilings, offering versatility in installation options.

The TSBF10NG is a dual-fuel infrared heater, allowing users to switch between natural gas and propane as needed. This flexibility makes it suitable for various environments and user preferences. The heater's robust construction ensures durability, while its adjustable heating levels allow for customized comfort.

For larger areas, the TSIR20NGT offers an enhanced heating capacity with similar infrared technology. This model is ideal for industrial or commercial spaces requiring efficient heating. With its advanced thermostat controls, users can maintain a consistent temperature while benefiting from lower operational costs.

Lastly, the MHBF6NG is a portable heating solution designed for versatility and convenience. This compact model is perfect for temporary heating needs, featuring an easy-to-use design that allows for quick setup and relocation. Its propane compatibility makes it a popular choice for outdoor events, workshops, or emergency heating situations.

Each model is equipped with advanced safety features, including automatic shutoff mechanisms and durable heat-resistant materials, ensuring peace of mind during operation. The Enerco line is engineered not only for performance but also for ease of maintenance, making them reliable options for users seeking efficient heating solutions. Overall, Enerco's HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG provide a range of effective heating options tailored to diverse environments and user needs, combining innovation with practical functionality.