Enerco TSIR20NGT, TSBF10NG, MHBF6NG, MHIR20NGT, HSIR20NGT Lighting Instructions, For IR only

Page 10

C.Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to re- place any part of the control system which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the all safety information included with and on the side of heater.

2.Check that gas supply to heater is on.

3.Push in gas control knob and slightly turn clock- wise to the OFF position (see figure 16).

Note: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force.

4.Wait five (5) minutes. Then smell for gas, in- cluding near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.

5.Push in gas control knob slightly and turn coun- terclockwise to PILOT/IGN and depress for five

(5) seconds.

Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system.

6.Push in control knob and rotate control knob back to OFF position then rotate counterclock- wise to PILOT/IGN position. This will light pilot. If needed gently keep rotating control knob back and forth while depressed until pilot lights.

7.Keep control knob depressed in for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 4, 5, 6 and 7.

If pilot does not stay lit, refer to Troubleshoot- ing, pages 14 & 15. Also, contact a qualified service person or gas supplier for repairs.

If control knob does not pop up when released, contact a qualified service person or gas sup- plier for repairs.

8.FOR IR10NG: When the pilot is lit, turn the con- trol knob to “LO” position to light heater. Leave on “LO” position until first burner tile has turned bright red (Figure 18)

FOR BF6NG and BF10NG: When the pilot is lit, turn the control knob to “HI” position to light heater.

9.FOR IR10NG: After first burner tile has turned bright red, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not operate heater between locked positions.

FOR BF6NG and BF10NG: After flame is estab- lished (see Burner Flame Pattern, Page 12) on “HI”, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not operate heater between locked positions.

Control Knob

Figure 16

 

Figure 17

 

Control Knob

Burner tile pattern

 

 

 

LOW

 

 

 

for IR only.

 

 

 

HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

Figure 18

CAUTION: Do not try to adjust heating level by using equipment shutoff valve.­

Unvented Natural Gas Fired Room Heater 10 Installation Instructions and Owner’s Manual

Image 10 Contents
TSBF30NGT TSBF20NGT HSBF10NG TSBF10NG MHIR30NGT MHIR20NGT Blue Flame Heaters­ Plaque Heaters­MHBF30NGT MHBF20NGT MHBF6NG HSBF30NGT HSBF20NGT HSIR30NGT HSIR20NGT HSIR10NG TSIR30NGT TSIR20NGT TSIR10NGCarbon Monoxide Poisoning PrecautionsNatural Gas Local Codes Safety DeviceThermostatic Control on Thermostat Models Ignition SystemVentilation AIR Determining the Type of Heater Location SpaceVentilation from Inside Building Ventilation from Outdoors Installation Check GAS TypeThis Installation Requires Locating Heater Fastening Heater to Wall Mounting BracketConnecting to GAS Supply Installing Bottom Mounting ScrewsInstalling Support Feet see figure Placing Heater on Mounting BracketTest pressure in Excess of ½ psig 3.5kPa Test Pressure Equal To or Less Than ½ psig 3.5 kPaFor Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram Operating Your HeaterLighting Instructions For IR onlyShutting OFF Heater To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF Burner only Pilot Stays LITPilot Flame Pattern Thermostat Control OperationInspecting Burner Burner Flame PatternCleaning Burner Pilot AIR Hole Inlet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Heater CabinetTroubleshooting Observed SYMPTOM­ Possible CAUSE­ REMEDY­Troubleshooting CON’T Observed SYMPTOM­ Possible CAUSE­ REMEDY­IR10NG­ IR20NGT­ IR30NGT­ SpecificationsBF6NG BF10NG­ BF20NGT BF30NGT­ IR20NGT Thermostat modelsBF20NGT BF30NGT IR30NGTITEM­ Part NO.­ For all models, Equipment shutoff valve with 1/8 NPT tapIR20NGT­ BF20NGT­ IR30NGT­ BF30NGT­ Not sold separately Must purchase Assembly * Items not shown ITEM­ Part NO.­ DESCRIPTION­ IR10NG, BF6NG and BF10NG Parts ListIR10NG­ BF6NG BF10NG­ IR10NG NON-Thermostat modelsBF6NG3 BF10NG Parts not Under Warranty REPLACEMENT­PARTSParts Under Warranty Technical ServiceUnvented Natural Gas Fired Room Heater Warranty Information Model ­ Serial No. ­ Date Purchased ­