Enerco TSIR10NG For all models, Equipment shutoff valve with 1/8 NPT tap, ITEM­ Part NO.­

Page 18

For all models, Equipment shutoff valve with 1/8” NPT tap.

IR20NGT, IR30NGT, BF20NGT, BF30NGT, BF20NGT, BF30NGT • PARTS LIST

This list contains replacement parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

ITEM­

 

 

 

PART NO.­

 

 

 

 

DESCRIPTION­

QTY.­

­

IR20NGT­

BF20NGT­

IR30NGT­

BF30NGT­

­

­

 

70600­

 

70600

 

70605

­

70605­

­

Cabinet assembly­

1-1­

70601­

­

70601­

 

70606

 

70606

­

Cabinet Top Panel­

1-2­

70603­

­

70603

 

70603

 

70603

­

Cabinet Right Panel­

1-3­

70602­

­

70602­

 

70607

 

70607

­

Cabinet back Panel­

1-4­

70704­

­

70704­

 

70704

 

70704

­

Cabinet Left Panel­

70608­

­

70608­

 

70609

 

70609

­

Lower Front panel assembly­

70742

­

70742­

 

70744

 

70744

­

Reflector Assembly­

70632

­

70633­

 

70634

 

70635

­

Burner Assembly­

70636­

­

70636­

 

70636

 

70636

­

Wall Mounting Bracket­

70637­

­

70637­

 

70637

 

70637

­

Thermostat Valve Mounting bracket­

70638­

­

70638­

 

70639

 

70639

­

Bezel – Reflector Front­

70640­

­

70640­

 

70640

 

70640

­

Thermostat Valve assembly­

70641­

­

70641­

 

70641

 

70641

­

Ignitor Module Mounting Bracket­

10­

70642­

­

---

­

70643

­

---

 

Back Plate­

11­

70644­

­

70644­

­

70644

 

70644

 

Ignitor Module, Battery powered­

12­

 

 

 

 

 

13­

70338­

­

70338­

­

70356

 

70338

 

Pressure regulator­

14­

---­

­

70646­

­

---

 

70648

 

Glass­

15­

---­

­

70647­

­

---

 

70649

 

Glass Mounting Bracket­

16­

70339­

­

70339­

­

70339

 

70339

 

ODS / Pilot Assembly­

17­

–­

 

 

 

 

 

18­

70650­

­

---­

­

70652

 

---

 

Gas Manifold­

19­

70651­

­

---­

­

70651

 

---

 

Gas Manifold Mounting Bracket­

21­

70655­

­

---­

­

70655

 

---

 

ODS mounting bracket­

22-1­

70741­

­

70741­

­

70743

 

70743

 

Heat Shield – Top ­

22-2­

70745­

­

70745­

­

70745

 

70745

 

Heat Shield – Right ­

22-3­

70751­

­

70753

­

70752

 

70754

 

Heat Shield – Back ­

23­

70663­

­

70663­

­

70663

 

70663

 

Regulator Mounting Bracket­

24­

70664­

­

70664­

­

70664

 

70664

 

Control / ignitor cover­

25­

70665­

­

70665­

­

70665

 

70665

 

Floor mount feet­

26­

70666­

­

70666­

­

70667

 

70667

 

Grill guard­

27-1­

­

—­

 

70668­

­

---

 

Orifice, 30, IR­

27-2­

—­

 

—­

 

—­

 

70669­

 

Orifice, 30, BF­

28-1

70670

 

 

 

 

Orifice, 20, IR

3

28-2

 

70671

 

 

 

Orifice, 20, BF

29

70740

 

70740

 

70740

 

70740

 

Fan Assembly

1

30

 

 

 

 

 

31

 

 

 

 

 

32

 

 

 

 

 

33-1

70756

 

70756

 

70756

 

70756

 

Heat Shield – Left

1

34

70674

 

70674

 

70674

 

70674

 

Digital Thermometer

1

35

70675

 

 

70676

 

 

Bracket, Top, Plenum Assembly

1

36

70675

 

 

70676

 

 

Bracket, Bottom, Plenum Assembly

1

Unvented Natural Gas Fired Room Heater 18 Installation Instructions and Owner’s Manual

Image 18
Contents TSBF30NGT TSBF20NGT HSBF10NG TSBF10NG MHIR30NGT MHIR20NGT Blue Flame Heaters­ Plaque Heaters­MHBF30NGT MHBF20NGT MHBF6NG HSBF30NGT HSBF20NGT HSIR30NGT HSIR20NGT HSIR10NG TSIR30NGT TSIR20NGT TSIR10NGPrecautions Carbon Monoxide PoisoningNatural Gas Local Codes Safety DeviceThermostatic Control on Thermostat Models Ignition SystemDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building Ventilation from Outdoors Installation Check GAS TypeThis Installation Requires Locating HeaterFastening Heater to Wall Mounting BracketConnecting to GAS Supply Installing Bottom Mounting ScrewsInstalling Support Feet see figure Placing Heater on Mounting BracketTest pressure in Excess of ½ psig 3.5kPa Test Pressure Equal To or Less Than ½ psig 3.5 kPaFor Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram Operating Your HeaterLighting Instructions For IR onlyShutting OFF Heater To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF Burner only Pilot Stays LITPilot Flame Pattern Thermostat Control OperationInspecting Burner Burner Flame PatternCleaning Burner Pilot AIR Hole Inlet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Heater CabinetTroubleshooting Observed SYMPTOM­ Possible CAUSE­ REMEDY­Troubleshooting CON’T Observed SYMPTOM­ Possible CAUSE­ REMEDY­Specifications IR10NG­ IR20NGT­ IR30NGT­BF6NG BF10NG­ BF20NGT BF30NGT­ IR20NGT Thermostat modelsBF20NGT BF30NGT IR30NGTFor all models, Equipment shutoff valve with 1/8 NPT tap ITEM­ Part NO.­IR20NGT­ BF20NGT­ IR30NGT­ BF30NGT­ Not sold separately Must purchase Assembly * Items not shown IR10NG, BF6NG and BF10NG Parts List ITEM­ Part NO.­ DESCRIPTION­IR10NG­ BF6NG BF10NG­ NON-Thermostat models IR10NGBF6NG3 BF10NG Parts not Under Warranty REPLACEMENT­PARTSParts Under Warranty Technical ServiceUnvented Natural Gas Fired Room Heater Warranty Information Model ­ Serial No. ­ Date Purchased ­
Related manuals
Manual 24 pages 60.4 Kb

MHBF10NG, HSIR20NGT, HSBF10NG, MHIR10NG, MHIR20NGT specifications

The Enerco HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG are a line of innovative heating solutions designed to meet various heating needs in both residential and commercial applications. Each model is engineered with advanced technologies and features that prioritize efficiency, performance, and user convenience.

The HSIR10NG is a high-efficiency infrared heater that operates on natural gas. It provides powerful heating with minimal energy consumption, utilizing infrared technology to warm objects and people directly rather than just the surrounding air. This results in faster heating and lower energy costs, making it an ideal choice for garages, workshops, or outdoor spaces.

Following closely is the TSIR10NG, another natural gas infrared heater known for its compact design and efficiency. This model features a state-of-the-art burner design that maximizes heat output while ensuring low emissions. The TSIR10NG is particularly suited for smaller spaces, providing targeted heating where it is needed most. It can easily be mounted on walls or ceilings, offering versatility in installation options.

The TSBF10NG is a dual-fuel infrared heater, allowing users to switch between natural gas and propane as needed. This flexibility makes it suitable for various environments and user preferences. The heater's robust construction ensures durability, while its adjustable heating levels allow for customized comfort.

For larger areas, the TSIR20NGT offers an enhanced heating capacity with similar infrared technology. This model is ideal for industrial or commercial spaces requiring efficient heating. With its advanced thermostat controls, users can maintain a consistent temperature while benefiting from lower operational costs.

Lastly, the MHBF6NG is a portable heating solution designed for versatility and convenience. This compact model is perfect for temporary heating needs, featuring an easy-to-use design that allows for quick setup and relocation. Its propane compatibility makes it a popular choice for outdoor events, workshops, or emergency heating situations.

Each model is equipped with advanced safety features, including automatic shutoff mechanisms and durable heat-resistant materials, ensuring peace of mind during operation. The Enerco line is engineered not only for performance but also for ease of maintenance, making them reliable options for users seeking efficient heating solutions. Overall, Enerco's HSIR10NG, TSIR10NG, TSBF10NG, TSIR20NGT, and MHBF6NG provide a range of effective heating options tailored to diverse environments and user needs, combining innovation with practical functionality.